Since the mid-1980's the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor 3000, 47-mm diameter) used at PNNL for self absorption effects. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Large error is associated with the sample filter analysis comparison and subsequently with the estimation of the absorption factor resulting in an inadequate method to estimate losses from self-absorption in the sample filter. The mass loading on the sample filter as determined after digestion and drying was approximately 0.08 mg cm; however, this value may not represent the total filter mass loading given that there may be undetermined losses associated with the digestion process. While it is difficult to determine how much material is imbedded in the filter, observations from the microscopy analysis indicate that the vast majority of the particles remain on the top of the filter. In comparing the results obtained, the continued use of 0.85 as a conservative correction factor is recommended.
机译:自1980年代中期以来,太平洋西北国家实验室(PNNL)使用值0.85作为从建筑物废气中收集的放射性微粒空气样品的活性自我吸收的校正因子,以进行环境监测。最近,人们努力评估PNNL处使用的当前颗粒放射性空气样品过滤器(Versapor 3000,直径47毫米)的自吸收效果。有两种用于表征样品的方法。从档案中选择了60个样品进行酸消解,以比较通过直接对过滤器进行气流比例计数所测量的放射性与在对酸消解过滤器并通过气流比例检测再次进行计数后获得的结果。选择了三十种不同的样品滤光片进行可见光显微镜检查,以评估滤光片的负载和颗粒特性。还考虑了质量负荷效应。较大的误差与样品过滤器的分析比较有关,随后与吸收系数的估算有关,导致估算样品过滤器自吸收损失的方法不足。消化和干燥后确定的样品过滤器上的质量负载约为0.08 mg cm;但是,鉴于可能存在与消化过程相关的不确定的损失,该值可能不代表总的过滤器质量负载。尽管很难确定过滤器中嵌入了多少材料,但通过显微镜分析发现,绝大多数颗粒保留在过滤器顶部。在比较获得的结果时,建议继续使用0.85作为保守校正因子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号