首页> 外文期刊>World Journal of Surgery: Official Journal of the Societe Internationale de Chirurgie, Collegium Internationale Chirurgiae Digestivae, and of the International Association of Endocrine Surgeons >Anticipated detection of imminent surgeon-patient barrier breaches. A prospective randomized controlled trial using an indicator underglove system.
【24h】

Anticipated detection of imminent surgeon-patient barrier breaches. A prospective randomized controlled trial using an indicator underglove system.

机译:预期会检测到即将出现的外科医生-患者障碍。使用指示性手套系统的前瞻性随机对照试验。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The double gloving indicator underglove system (IUS) is based on a colored detection of the outer glove perforation. Our objective was to determine the IUS efficiency to detect outer glove perforations and to reduce the risks of blood and body fluids exposure, warning the surgeon before the breach of the surgeon-patient barrier (SPB). A series of 100 visceral surgical procedures were randomly assigned to either double (IUS) or single gloving. The noticed glove perforations (using the water test method) and the IUS efficiency were analyzed in 99 procedures. In 49 single-gloving procedures, 19 perforations were noticed: one was immediately perceived (perceived accidental exposure, PAE); 3 were discovered as the gloves were being removed, and 15 were undetected before the water test (unperceived prolonged contact, UPC). In 50 double-gloving procedures (IUS), 16 perforations were noticed, all of them involving only the outer glove: the IUS allowed immediate detection of 3 perforations without any blood exposure; 13 other perforations went undetected but without any UPC. In conjunction with the protective quality of double gloving, the IUS allows detection of significant breaches of the outer glove before the breach of the SPB.
机译:双手套指示手套系统(IUS)基于外部手套孔眼的彩色检测。我们的目标是确定IUS的效率,以检测手套的外部穿孔并降低血液和体液暴露的风险,并在违反外科手术患者屏障(SPB)之前向外科医师发出警告。将一系列100种内脏外科手术程序随机分配给双(IUS)或单手套。在99个步骤中分析了手套穿孔(使用水测试方法)和IUS效率。在49次单手套操作中,发现19眼穿孔:立即察觉到一个(感知到意外暴露,PAE);在移开手套时发现了3个,在进行水测试之前未发现15个(未察觉的长时间接触,UPC)。在50次双手套手术(IUS)中,发现了16个穿孔,所有穿孔仅涉及外手套:IUS允许立即检测到3个穿孔,而无任何血液接触。未发现其他13个穿孔,但没有任何UPC。结合双手套的防护质量,IUS可以在SPB断裂之前检测到外手套的明显断裂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号