Spectroscopic Analysis of Ultraviolet Lamps for Disinfection of Air in Hospitals

机译:用于医院空气消毒的紫外线灯的光谱分析

获取原文
获取原文并翻译 | 示例
       

摘要

In order to have feasibility study of ultraviolet lamps for air disinfection in hospitals, a number of lamps were studied spectroscopically. It was required to understand if these lamps really emitted 253.7 run. Was the radiation intense enough to disinfect the surrounding air in the hospital? And to know about the percent transmission of the UV rays through the glass of the lamps. The intensity and UV dose were calculated at various distances in air from the lamps. While putting 1-min exposure time in the reciprocity law, the intensity/distance and dose/ distance graphs were drawn for various lamps. From the trend line of the graph the distance at which the lamp emitted 10 uW/cm2 was calculated. In this study the 1-min exposure time was considered, using the Riley's designed upper room air disinfection data for 90% kill rate. In the light of the results these lamps were considered fit to be installed either in the air ducts or in the upper room at certain distances for air disinfection, and suggestions were given for the improvement of the system proposed.
机译:为了进行医院空气消毒用紫外线灯的可行性研究,对许多灯进行了光谱学研究。需要了解这些灯是否真正发出了253.7的光。辐射强度足以消毒医院周围的空气吗?并了解紫外线通过灯杯的透射百分比。在距灯的空气中不同距离处计算强度和紫外线剂量。将互易定律中的1分钟曝光时间作为依据,绘制了各种灯的强度/距离和剂量/距离图。根据曲线图的趋势线,可以计算出灯发出10 uW / cm2的距离。在这项研究中,使用莱利(Riley)设计的上层室内空气消毒数据以90%的杀灭率来考虑1分钟的暴露时间。根据结果​​,这些灯被认为适合于在空气管道中或在较高距离的较高空间中安装,以进行空气消毒,并提出了改进建议系统的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号