...
首页> 外文期刊>Water Science and Technology >Survival of indicators of bacterial and viral contamination in wastewater subjected to low temperatures and freezing: application to cold climate waste stabilisation ponds
【24h】

Survival of indicators of bacterial and viral contamination in wastewater subjected to low temperatures and freezing: application to cold climate waste stabilisation ponds

机译:低温和冷冻废水中细菌和病毒污染指标的生存:在寒冷气候下的废物稳定池中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

The survival of bacterial and viral pollution indicators and Salmonella in urban wastewaters under freezing conditions (-14degreesC for up to 60 days) is reported. Presumptive, total and faecal coliforms (PC, TC, FC), salmonellae and coliphages were tested. The dynamics of somatic coliphage (E coli C) and F-pili specific coliphage inactivation were compared at 4degreesC and 25degreesC over various run times. On freezing of the wastewater, it was found that PC, TC and FC showed a first rapid phase (days) of inactivation followed by a slower second phase (up to 4 weeks) and then stabilisation at between 1-10% of the initial population size, depending on the wastewater sample used. Salmonella spp. were detectable in 0.1 ml of raw wastewater and were still detected up to 2 days after freezing but none were detected in 100 ml samples after 4, 42 and 60 days, although microbiologically similar but antigenically different forms were found. Viral indicators of pollution showed a slow but constant decrease in viability during the first month but then stabilised at between 10-20% survivors (10% in somatic E coli C phages, 15.8% in somatic Salmonella phages and 17.9% in F-pili specific coliphages). Using electron microscopy, no difference in susceptibility to freezing could be detected with respect to morphological phage types, which were either small icosahedral particles or complex tailed phages. The study of viral indicators at 4degreesC versus 25degreesC showed a higher survival of the various coliphages over time at 4degreesC. F-pili specific leviviridae were particularly susceptible to the antiviral factors at 25degreesC and no viable units per ml were detected after one month at that temperature, whereas somatic coliphages were detected in higher numbers after this period, especially at 4degreesC. [References: 22]
机译:据报道,细菌和病毒污染指标以及沙门氏菌在冰冻条件下(-14摄氏度,长达60天)在城市废水中的存活率。测试了推定的,总的和粪便的大肠菌群(PC,TC,FC),沙门氏菌和大肠杆菌。在不同的运行时间下,分别在4°C和25°C下比较了体细胞噬菌体(E. coli C)和F-菌毛特异性噬菌体灭活的动力学。在冻结废水时,发现PC,TC和FC表现出第一个快速失活阶段(天),然后是一个较慢的第二阶段失活(长达4周),然后稳定在初始种群的1-10%之间大小,取决于所用废水样品。沙门氏菌尽管在微生物学上相似但在抗原上有所不同,但在0.1 ml的原废水中可检测到它们,并且在冷冻后直至2天仍可检测到,但在4、42和60天后100 ml样品中均未检测到。污染的病毒指标显示,在第一个月内,生存能力缓慢但持续下降,但随后稳定在10%至20%的存活率之间(体大肠杆菌C噬菌体为10%,沙门氏菌噬菌体为15.8%,F菌毛特异性为17.9%噬菌体)。使用电子显微镜,就形态噬菌体类型(小二十面体颗粒或复杂尾噬菌体)而言,未检测到冷冻敏感性。对4°C和25°C的病毒指标进行的研究表明,在4°C下,随着时间的推移,各种噬菌体的存活率更高。 F-菌毛特异的活病毒科在25°C时特别容易受到抗病毒因子的影响,在此温度下一个月后未检测到每毫升有活力的单位,而在此期间,尤其是在4°C时,体细胞中的噬菌体数量更高。 [参考:22]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号