The experience with the upgrading of 14 treatment plants to N and P removal is presented. For all plants it has been possible to fulfil the effluent standards. Through process optimization it has been possible to achieve a stable biological P-removal. The introduction of control systems based on on-line sensors for ammonia, nitrate and phosphate has resulted in a more stable effluent quality and an increased capacity. The experience also shows that it can be very difficult to predict and control the changes in the industrial load From this it is concluded that instead of spending a lot of time on fine-tuning the design criteria in the design phase, it may be better to incorporate a considerable flexibility into the design, allowing the processes to be adjusted to the changing operational conditions during time. (C) 1998 IAWQ. Published by Elsevier Science Ltd [References: 2]
机译:介绍了将14个处理厂升级为脱氮除磷的经验。对于所有工厂,都有可能达到废水标准。通过工艺优化,可以实现稳定的生物除磷。基于氨,硝酸盐和磷酸盐在线传感器的控制系统的引入,使废水质量更加稳定并提高了处理能力。经验还表明,预测和控制工业负载的变化可能非常困难。由此可以得出结论,与其在设计阶段花费大量时间来微调设计标准,不如说是更好的选择。在设计中融入了相当大的灵活性,从而可以根据时间的变化来调整流程。 (C)1998 IAWQ。由Elsevier Science Ltd发布[参考:2]