PURPOSE: This prospective clinical study evaluated the performance of 290 tapered, anodic oxidized (TiUnite) titanium implants placed in compromised bone in a consecutive series of 126 patients. MATERIALS AND METHODS: Inclusion criteria were: (1) a need for dental implants in either a single-tooth or partially edentulous segment, (2) sufficient medical fitness to undergo the procedure, (3) enough bone to enable placement of a 10-mm or longer implant, and (4) compromised bone, as judged by computerized tomography and confirmed by clinical findings, in at least one implant site. Implants were placed and left unloaded for at least 6 months (mean 9.9 +/- 3.9 months) before placement of the first provisional prosthesis and followed for at least 3 years after loading. Marginal bone was measured by an independent radiologist. RESULTS: A second-stage uncovering was required for approximately half the implants. Failure of osseointegration was observed for only two implants; all other implants provided the intended prosthetic support during the entire observation period. The overall implant survival rate after 3 years of loading was 99.3%. The average mean changes in the marginal bone level showed stability (-2.70 mm, -2.67 mm, and -2.74 mm at 1, 2, and 3 years postloading, respectively). CONCLUSIONS: Using a modified surgical technique that minimized the osteotomy dimensions, tapered implants with an oxidized surface proved to be a predictable support for fixed prostheses in both grafted and ungrafted compromised bone. Marginal bone levels were stable throughout at least 3 years of follow-up.
机译:目的:这项前瞻性临床研究评估了连续126例患者中290枚锥形,阳极氧化(TiUnite)钛植入物植入受损骨中的性能。材料和方法:纳入标准为:(1)在单齿或部分缺牙的部分需要种植牙;(2)有足够的医疗适应性以接受该手术;(3)有足够的骨骼以放置10颗牙齿。至少在一个种植体部位,经计算机断层扫描判断并经临床发现证实,其直径为4毫米或更长,并且(4)骨骼受损。在放置第一个临时假体之前,将植入物放下并放置至少6个月(平均9.9 +/- 3.9个月),然后再放置至少3年。边缘骨由独立的放射科医生测量。结果:大约一半的植入物需要第二阶段的露出。仅两个植入物观察到骨整合失败。所有其他植入物在整个观察期内均提供了预期的假体支撑。加载3年后,植入物的总生存率为99.3%。边缘骨水平的平均平均变化显示稳定(分别在加载后1、2和3年时为-2.70 mm,-2.67 mm和-2.74 mm)。结论:使用改良的外科手术技术以最小化截骨术的尺寸,带有氧化表面的锥形植入物被证明是对移植的和未移植的受损骨中固定假体的可预测支持。在至少三年的随访中,边缘骨水平保持稳定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号