Units 1 and 2 at Staudinger Power Station arc cyclone-fired with 100 % fly ash return. The units,which were built in 1965, were retrofitted in 1989/90 with flue gas nitrogen removal plant. Thecatalysers showed themselves to be especially weak in respect of pollution. This paper reports on theeffects on adjoining plant and on measures taken to prevent pollution.
机译:Staudinger电站的1号和2号机组以100%的粉煤灰回旋燃烧。这些装置建于1965年,并于1989/90年度进行了烟气脱氮装置的改造。催化剂在污染方面表现出特别弱的作用。本文报告了对邻近植物的影响以及为防止污染所采取的措施。