A comparison between the v-gel supraglottic airway device and the cuffed endotracheal tube for airway management in spontaneously breathing cats during isoflurane anaesthesia.

机译:在异氟烷麻醉期间自发呼吸的猫中的v-gel声门上气道装置和带气管的气管插管的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: To compare airway management using the v-gel supraglottic airway device (v-gel SGAD) to that using an endotracheal tube (ETT), with respect to practicability, leakage of volatile anaesthetics and upper airway discomfort in cats. Study design: Prospective, randomized clinical trial. Animals: Twenty European Shorthair cats (9 males, 11 females), weighing 3.3+or-0.7 kg. Methods: Cats were randomly allocated to one of two groups, in which the airway was managed by either the v-gel SGAD or a cuffed ETT, and anaesthetized for neutering procedures. The dose of propofol necessary to insert the ETT or v-gel SGAD; time from the first injection of propofol to the first clinically acceptable reading on the capnograph; leakage of isoflurane around the airway device; and upper airway discomfort scores during recovery and during the first 24 hours after anaesthesia were recorded. Continuous and discrete variables were analyzed with the Mann-Whitney U-test and the Pearson chi-squared test, respectively. Results were considered statistically significant if p<0.05. Results: Time from the first injection of propofol to the first clinically acceptable reading on the capnograph was significantly shorter in the v-gel group. The ETT group showed significantly more stridor during recovery. No other significant differences were found. Conclusions and clinical relevance: Airway management with the v-gel SGAD is a sound and practicable alternative to endotracheal intubation with an ETT. However, larger prospective trials will be needed to draw firm conclusions on the benefits and/or drawbacks of the use of v-gel SGAD for airway management in cats.
机译:目的:比较猫的v-gel声门上气道装置(v-gel SGAD)和气管内导管(ETT)的气道处理方法在实用性,挥发性麻醉剂泄漏和上呼吸道不适方面的关系。研究设计:前瞻性随机临床试验。动物:20只欧洲短毛猫(9头雄性,11头雌性),重3.3或-0.7千克。方法:将猫随机分为两组,其中气管由v-gel SGAD或带套囊的ETT控制,并麻醉以进行绝育手术。插入ETT或v-gel SGAD所需的异丙酚剂量;从首次注射异丙酚到二氧化碳分析仪上第一个临床可接受的读数的时间;异氟醚在气道装置周围泄漏;记录恢复期间和麻醉后最初24小时内的上呼吸道不适分数。连续变量和离散变量分别使用Mann-Whitney U检验和Pearson卡方检验进行了分析。如果p <0.05,则认为结果具有统计学意义。结果:v-gel组从首次注射异丙酚到首次在二氧化碳分析仪上获得临床可接受的读数的时间明显缩短。 ETT组在恢复过程中表现出明显更多的喘鸣声。没有发现其他显着差异。结论和临床意义:v-gel SGAD的气道管理是使用ETT进行气管插管的一种合理可行的选择。但是,将需要进行较大的前瞻性试验,以得出关于将v-gel SGAD用于猫气道管理的利弊的确切结论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号