BACKGROUND: Deterioration of platelet (PLT) quality during storage is accompanied by an increase in lactate production, indicating a decrease in mitochondrial function. In this study, the optimal conditions under which the fluorescent dye JC-1 can be used to detect changes in mitochondrial function in PLTs were established. STUDY DESIGN AND METHODS: PLTs were incubated at 37 degrees C in synthetic medium under various conditions of JC-1 loading. In the presence of a high membrane potential, this dye accumulates in the mitochondria with a concomitant increase in red fluorescence. After JC-1 loading, the ratio of red (FL2) to green (FL1) fluorescence was determined by flow cytometry. RESULTS: The FL2-to-FL1 ratio of PLTs (3 x 10(7)/mL, loaded with 0.5 micromol/L JC-1) amounted to about 5 in 1-day-old PLTs. At higher dye concentrations, the FL2-to-FL1 ratio was significantly lower, suggesting uncoupling by the dye itself. Plasma concentrations above 3 percent significantly affected the JC-1 signal. The FL2-to-FL1 ratio showed a dose-dependent decrease to an uncoupler of oxidative phosphorylation or to inhibition of the respiratory chain. JC-1-loaded PLTs showed a clear decrease in FL2-to-FL1 ratio after prolonged storage or upon ultraviolet (UV) illumination. Only after UV treatment did changes in JC-1 signal correlate with changes in CD62P expression. CONCLUSION: The FL2-to-F1 ratio of PLTs loaded with JC-1 is a reliable and sensitive indicator of the mitochondrial membrane potential, provided that the proper experimental conditions have been applied.
机译:背景:在储存过程中血小板(PLT)质量的恶化伴随着乳酸产量的增加,表明线粒体功能的下降。在这项研究中,建立了可用于检测PLT线粒体功能变化的荧光染料JC-1的最佳条件。研究设计与方法:将PLT在JC-1上不同载量条件下于37摄氏度的合成培养基中孵育。在高膜电位的情况下,该染料积聚在线粒体中,伴随着红色荧光的增加。加载JC-1后,通过流式细胞仪确定红色(FL2)与绿色(FL1)荧光的比率。结果:在1天龄的PLT中,PLT的FL2与FL1比率(3 x 10(7)/ mL,装有0.5 micromol / L JC-1)约为5。在较高的染料浓度下,FL2与FL1的比率明显较低,这表明染料本身会解偶联。血浆浓度超过3%会显着影响JC-1信号。 FL2与FL1的比例显示出剂量依赖性降低氧化磷酸化的解偶联剂或抑制呼吸链。长时间存放或在紫外线(UV)照射下,装有JC-1的PLT的FL2-FL1比值明显降低。仅在紫外线处理后,JC-1信号的变化才与CD62P表达的变化相关。结论:载有JC-1的PLT的FL2-F1比值是线粒体膜电位的可靠且灵敏的指标,只要已应用适当的实验条件即可。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号