...
首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >Prediction of red cell and blood volumes distribution by various nomograms: do current nomograms overestimate?
【24h】

Prediction of red cell and blood volumes distribution by various nomograms: do current nomograms overestimate?

机译:通过各种列线图预测红细胞和血容量分布:当前的列线图是否高估了?

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Currently used formulas for estimation of a person's red cell volume (RCV) by weight and height are decades old and were based on the use of 51Cr isotopes and on a sample population, which may not be reflective of today's population. In this study, the accuracy and precision of the use of 99mTc RCV measurements in volunteers more typical of today's population were evaluated. STUDY DESIGN AND METHODS: The subjects were volunteers who met the requirements for a standard blood donation. RESULTS: The mean +/- standard deviation (SD) 99mTc RCV for 127 males (mean weight, 83.2 kg; height, 180 cm) was 2062 +/- 339 mL, and for 101 females (mean weight, 69.5 kg; height, 166 cm) it was 1320 +/- 201 mL. These results were highly correlated with RCV results with the standard extrapolation 51Cr method with stored red blood cells (RBCs) and highly consistent (within +/-10%) by repeated measurements with the same 22 donors over a 3.5-year period. The RCV results correlated with estimates from the current formulas, but were on average 11 to 14 percent lower. CONCLUSION: The studies demonstrated that 99mTc is a reproducible and precise method for determination of a person's RCV and that current formulas may significantly overestimate the RCV of today's population. This is likely the result of a shift in population characteristics over the past four decades as reflected by an increased mean body mass index (from 25 to 28 kg/m2), which has not resulted in a proportionally increased RCV.
机译:背景:目前使用的通过体重和身高估算人的红细胞体积(RCV)的公式已有数十年历史,并且基于51Cr同位素的使用和样本人群,这可能无法反映当今的人群。在这项研究中,评估了在当今人口中更为典型的志愿者中使用99mTc RCV测量的准确性和精确性。研究设计和方法:受试者是符合标准献血要求的志愿者。结果:127例男性(平均体重83.2千克;身高180厘米)的平均+/-标准偏差(SD)99mTc RCV为2062 +/- 339毫升,而101例女性(平均体重69.5千克;身高, 166厘米)为1320 +/- 201毫升。这些结果与使用存储的红细胞(RBC)的标准外推51Cr方法的RCV结果高度相关,并且通过在3.5年的时间内对相同的22个供体进行重复测量,高度一致(在+/- 10%以内)。 RCV结果与当前公式的估计值相关,但平均降低了11%至14%。结论:研究表明,99mTc是测定个人RCV的可再现且精确的方法,当前公式可能会大大高估当今人口的RCV。这可能是过去四十年人口特征发生变化的结果,这反映在平均体重指数增加(从25 kg / m2到28 kg / m2)上,而这并未导致RCV的增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号