首页> 外文期刊>Surface and Interface Analysis: SIA: An International Journal Devoted to the Development and Application of Techniques for the Analysis of Surfaces, Interfaces and Thin Films >Effects of vacuum heating in AISI 410 and AISI 321 stainless steels' surface layer revealed by SIMS/GDMS depth profile analysis
【24h】

Effects of vacuum heating in AISI 410 and AISI 321 stainless steels' surface layer revealed by SIMS/GDMS depth profile analysis

机译:SIMS / GDMS深度剖面分析揭示了AISI 410和AISI 321不锈钢表面层中真空加热的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Vacuum annealing of steels is employed for out-gassing elements, surface activation and in different production purposes. Such procedure was applied for chromium-nickel AISI 321 and chromium AISI 410 stainless steels used in aviation technologies. Depth profile analysis of the samples annealed in vacuum for 120 min. in 750 and 950 °C was performed by using two methods: SIMS and glow discharge mass spectrometry (GDMS). SIMS data were obtained with a 5 keV Ar + ion gun. In GDMS analyzer, d.c. glow discharge was induced by 1.5 kV d.c. voltage in 1 mbar Ar pressure. Analyses of AISI 321 samples annealed in 750 °C show enrichment of titanium, chromium and manganese in the depth range of 150 nm, and depletion in iron and nickel within this range. The sample treated in 950 °C shows mainly Ti enrichment into 300 nm depth. Vacuum heating of AISI 410 steel sample in 750 °C causes formation of 150-nm-thick surface layer enriched in Cr and Mn and depleted in Fe. In turn, 950 °C treatment results in only some increasing of Mn and Ni concentration within 70 nm distance from the surface. The results obtained by SIMS and GDMS confirm each other. However, higher depth profile resolution was obtained by GDMS due to the lower sputtering energy (1.5 kV glow discharge) and due to the use of multidirectional ion bombardment instead of unidirectional bombardment by ion beam in the SIMS method.
机译:钢的真空退火可用于除气元素,表面活化以及用于不同的生产目的。该程序适用于航空技术中使用的铬镍AISI 321和铬AISI 410不锈钢。真空退火120分钟的样品的深度分布分析。通过两种方法在750和950°C下进行加热:SIMS和辉光放电质谱(GDMS)。 SIMS数据使用5 keV Ar +离子枪获得。在GDMS分析仪中,直流电1.5 kV d.c引起辉光放电。电压为1 mbar Ar压力。 AISI 321样品在750°C退火后的分析表明,钛,铬和锰在150 nm深度范围内富集,铁和镍在该范围内富集。在950°C下处理的样品主要显示Ti富集至300 nm深度。在750°C的温度下对AISI 410钢样品进行真空加热会导致形成150 nm厚的表面层,该表面层富含Cr和Mn,而Fe则贫乏。反过来,在950°C的处理条件下,距表面70 nm处的Mn和Ni浓度仅增加一些。 SIMS和GDMS获得的结果相互证实。但是,由于GDMS获得了更低的溅射能量(1.5 kV辉光放电),并且由于在SIMS方法中使用了多方向离子轰击而不是离子束单向轰击,因此获得了更高的深度轮廓分辨率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号