We aimed to develop and validate the first robotic-based instrument and procedure for assessing upper extremity motor impairments in patients with stroke and to test its discriminative power.The ReoGo robotic rehabilitation platform was used to design a novel, upper limb functionality assessment tool, the Reo Scale Assessment (RSA). We used the RSA to evaluate 100 patients with stroke. The RSA items were tested for internal consistency and submitted to factor analysis. The Fugl-Meyer (FM) motor test, the Wolf Motor Function Test (WMFT), and the Action Research Arm Test (ARAT) were used to examine the validity of the RSA. RSA scores were compared and correlated with the scores of the 3 scales. The discriminative power of the RSA was tested against the FM impairment levels by analysis of variance.The total RSA score correlated closely with the upper extremity scores of the FM, WMFT, and ARAT (r = 0.95, 0.93, and 0.90, respectively). The RSA was able to discriminate between low, moderate, and high functioning patients (86% agreement with FM). Principal component analysis revealed that the RSA coefficients loaded on 3 tested components: proximal, distal, and force.Our results provide strong evidence that the validity of the RSA is comparable with that of the FM, WMFT, and ARAT. The objective measuring and scoring systems of the robotic RSA make it an efficient tool for assessing motor function of stroke patients in clinical and research settings. Additional studies are needed to test the reliability and sensitivity of the RSA.
机译:我们旨在开发和验证首款基于机器人的仪器和程序,用于评估中风患者的上肢运动障碍并测试其判别力.ReoGo机器人康复平台用于设计新颖的上肢功能评估工具, Reo量表评估(RSA)。我们使用RSA评估了100名中风患者。对RSA项目进行了内部一致性测试,并进行了因子分析。使用Fugl-Meyer(FM)运动测试,Wolf运动功能测试(WMFT)和动作研究手臂测试(ARAT)来检查RSA的有效性。比较RSA得分并将其与3个量表的得分相关联。通过方差分析测试RSA对FM损伤水平的判别力.RSA总得分与FM,WMFT和ARAT的上肢得分密切相关(分别为r = 0.95、0.93和0.90)。 RSA能够区分低,中和高功能患者(与FM达成86%的一致性)。主成分分析表明,RSA系数加载在三个测试成分上:近端,远端和受力。我们的结果提供了有力的证据,证明RSA的有效性与FM,WMFT和ARAT相当。 RSA机器人的客观测量和评分系统使其成为评估临床和研究机构中风患者运动功能的有效工具。需要进行其他研究以测试RSA的可靠性和敏感性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号