...
首页> 外文期刊>Thrombosis Research: An International Journal on Vascular Obstruction, Hemorrhage and Hemostasis >Effect of prothrombin time outlier exclusion rules on ISI calibration in multicentre studies.
【24h】

Effect of prothrombin time outlier exclusion rules on ISI calibration in multicentre studies.

机译:凝血酶原时间异常排除规则对多中心研究中ISI校准的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

International Sensitivity Index (ISI) calibration is based on prothrombin time (PT) determinations in fresh plasma samples of healthy (normal) individuals and patients treated with vitamin K-antagonists (VKA). The ISI is calculated from the slope of the orthogonal regression line of the log(PT) results. The ISI calibration model is based on the assumption that the mean logarithms of the PT's of the normals are found on the orthogonal regression line derived using patients' samples. According to World Health Organization (WHO) guidelines, patients' samples with International Normalized Ratio (INR) beyond the 1.5 to 4.5 interval shall be excluded for ISI calibration. According to the WHO guidelines, outlier samples are defined as those at a perpendicular distance from the orthogonal regression line greater than 3 residual standard deviations, and shall be excluded as well. The purpose of the present study was to assess the effect of sample exclusion on ISI calibration, using the data base of three historic multicenter studies performed in 1990, 1995 and 2005, respectively. Various rules for sample exclusion were tried. In comparison to calibration without any exclusion, between-laboratory variation of the ISI was slightly reduced by sample exclusion using the WHO rule. Furthermore, the adequacy of the ISI calibration model was improved. The effect of the WHO sample exclusion rule on the mean value of the ISI of the current International Standards for thromboplastins was not greater than approximately 1%. It is concluded that the WHO rule for sample exclusion is appropriate for reliable ISI calibration.
机译:国际敏感性指数(ISI)校准基于健康(正常)个体和接受维生素K拮抗剂(VKA)治疗的患者的新鲜血浆样品中凝血酶原时间(PT)的测定。根据log(PT)结果的正交回归线的斜率计算ISI。 ISI校准模型基于以下假设:法线PT的平均对数是在使用患者样本得出的正交回归线上找到的。根据世界卫生组织(WHO)指南,国际标准化比率(INR)超过1.5到4.5间隔的患者样本应排除在ISI校准范围之外。根据WHO准则,离群样本定义为距正交回归线的垂直距离大于3个残留标准偏差的样本,并且也应排除在外。本研究的目的是使用分别在1990年,1995年和2005年进行的三项历史性多中心研究的数据库,评估样品排除对ISI校准的影响。尝试了各种排除样品的规则。与不进行任何排除的校准相比,使用WHO法则通过排除样品可以稍微降低ISI的实验室间差异。此外,ISI校准模型的适当性得到了改善。 WHO样本排除规则对当前国际凝血活酶标准品的ISI平均值的影响不大于约1%。结论是,WHO的样品排除规则适用于可靠的ISI校准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号