首页> 外文期刊>Therapeutic Drug Monitoring >Simplified high-performance liquid chromatographic method for the determination of gentamicin sulfate in a microsample of plasma: comparison with fluorescence polarization immunoassay.
【24h】

Simplified high-performance liquid chromatographic method for the determination of gentamicin sulfate in a microsample of plasma: comparison with fluorescence polarization immunoassay.

机译:简化的高效液相色谱法测定血浆微量样品中的硫酸庆大霉素:与荧光偏振免疫分析法比较。

获取原文
获取原文并翻译 | 示例
       

摘要

The authors describe a simplified high-performance liquid chromatographic (HPLC) method for the determination of gentamicin sulfate (GEN) in microsamples of plasma using 9-fluorenylmethyl chloroformate (FMOC) as a derivatizing agent and neomycin sulfate as the internal standard (IS). The drug and IS were separated on a 4 microm (particle size), 8 x 100 mm Nova-Pak C18 radial compression cartridge using a mixture of 84.5% acetonitrile and 15.5% water at a flow rate of 2.5 mL/min. The compounds were detected fluorometrically in the effluent at excitation and emission wavelengths of 260 nm and 315 nm, respectively. Sample preparation was performed on 50 microL of plasma using a simple liquid-liquid extraction followed by a room-temperature derivatization procedure. No interference from any endogenous substance or concurrently used drug was observed, and the retention times of the IS and three major components of GEN were 12.4, 19.5, 23.6, and 27.6 min, respectively. The concentration of the GEN in plasma for the range of 0.2-20.0 microg/mL was linearly (r > .997) related to the peak height ratio of the sum of the three major GEN peaks to that of the IS, with CV value at 0.3, 7.5, and 15 microg/mL being <3.61%. A comparison of the results from this assay versus fluorescence polarization immunoassay (TDx) showed a close agreement between the two methods with r = 0.994. This assay is currently being used to monitor GEN and investigate its pharmacokinetics in pediatric patients.
机译:作者介绍了一种简化的高效液相色谱(HPLC)方法,使用9-芴基甲基氯甲酸酯(FMOC)作为衍生剂和硫酸新霉素作为内标(IS)测定血浆微量样品中的硫酸庆大霉素(GEN)。使用84.5%乙腈和15.5%水的混合物,以2.5毫升/分钟的流速,在4微米(粒径),8 x 100毫米Nova-Pak C18径向压缩药筒上分离药物和IS。分别在激发和发射波长分别为260 nm和315 nm的荧光发射光谱中检测化合物。使用简单的液-液萃取,然后进行室温衍生化步骤,对50微升血浆进行样品制备。没有观察到任何内源性物质或同时使用的药物的干扰,IS和GEN的三个主要成分的保留时间分别为12.4、19.5、23.6和27.6分钟。血浆中GEN的浓度在0.2-20.0 microg / mL的范围内与三个主要GEN峰之和与IS的峰高之比呈线性关系(r> .997),CV值为0.3、7.5和15微克/毫升<3.61%。该测定与荧光偏振免疫测定(TDx)结果的比较表明,两种方法之间的一致性很高,r = 0.994。该测定法目前被用于监测GEN并研究其在儿科患者中的药代动力学。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号