首页> 外文期刊>Therapeutic Drug Monitoring >Laboratory evaluation and field application of roadside oral fluid collectors and drug testing devices.
【24h】

Laboratory evaluation and field application of roadside oral fluid collectors and drug testing devices.

机译:路边口服液收集器和药物测试装置的实验室评估和现场应用。

获取原文
获取原文并翻译 | 示例
           

摘要

This study was a part of a collaborative U.S./E.U. international research effort (Roadside Testing Assessment, ROSITA II) to assess illegal drug use among motor vehicle operators suspected of driving while under the influence of drugs and to evaluate the effectiveness of point-of-collection oral fluid drug detection technologies. A goal of the study was to assess commercial oral fluid drug testing devices for potential use in law enforcement. Ten devices were evaluated in the laboratory for their ability to meet manufacturers' claimed (and proposed) cutoff concentrations for the detection of amphetamine(s), cocaine/metabolite, opiates, cannabinoids, and benzodiazepines (2 devices). The field study portion of the research was conducted in major cities in the United States and Western Europe by teams of scientists working in collaboration with the local police. In Salt Lake City, Utah, the Drugwipe, Securetec, Ottobrunn, Germany (Securetec) oral fluids drug testing device was also evaluated in the field by testing suspected drug-impaired drivers. During the initial phase of the field study, 40 subjects were recruited. Drugwipe results were compared with laboratory-based immunoassay and mass spectrometry results and demonstrated that calculated sensitivities were between 75% and 100% depending on drug class. Specificities varied from 36% for cannabinoids to over 95% for opiates. During the second phase of the field study, 267 subjects were recruited. The Drugwipe sensitivities were 36.4%, 35.9%, 42.9%, and 7.7%, respectively, for amphetamine(s), cocaine, opiates, and cannabinoids. The Drugwipe specificities were 99.2%, 97.4%, 99.6%, and 99.6%, respectively, for amphetamine(s), cocaine, opiates, and cannabinoids. Drugwipe failed to meet the study criteria for acceptable device performance, required performance sensitivities, and specificities 90% or greater.
机译:这项研究是美国/欧盟合作组织的一部分。国际研究工作(路边测试评估,ROSITA II),以评估涉嫌在药物影响下驾驶的机动车驾驶员中的非法药物使用情况,并评估收集点口服液药物检测技术的有效性。该研究的目的是评估可能在执法中使用的商业口服液体药物测试设备。在实验室中评估了十种设备,满足制造商声称的(和建议的)临界浓度用于检测苯丙胺,可卡因/代谢产物,阿片类药物,大麻素和苯并二氮杂(2种设备)的能力。该研究的实地研究部分是在美国和西欧的主要城市,由与当地警察合作的科学家团队进行的。在犹他州盐湖城,德国Ottobrunn Securetec的Drugwipe(Securetec)口服液药物测试装置也通过测试可疑的药物受损驾驶员进行了现场评估。在现场研究的初始阶段,招募了40名受试者。将Drugwipe结果与基于实验室的免疫分析和质谱结果进行了比较,结果表明,根据药物类别,计算出的敏感性在75%至100%之间。特异性从大麻素的36%到阿片类药物的95%以上不等。在现场研究的第二阶段,招募了267名受试者。苯丙胺,可卡因,鸦片和大麻素的药擦敏感性分别为36.4%,35.9%,42.9%和7.7%。苯丙胺,可卡因,鸦片和大麻素的药擦特异性分别为99.2%,97.4%,99.6%和99.6%。 Drugwipe未能满足可接受的设备性能,所需的性能敏感性和90%或更高的特异性的研究标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号