首页> 外文期刊>The Southeast Asian journal of tropical medicine and public health >Improving microbial air quality in air-conditioned mass transport buses by opening the bus exhaust ventilation fans.
【24h】

Improving microbial air quality in air-conditioned mass transport buses by opening the bus exhaust ventilation fans.

机译:通过打开公共汽车排气通风风扇来改善空调大客车中的微生物空气质量。

获取原文
获取原文并翻译 | 示例

摘要

The air quality in air-conditioned mass transport buses may affect bus drivers' health. In-bus air quality improvement with the voluntary participation of bus drivers by opening the exhaust ventilation fans in the bus was implemented in the Seventh Bus Zone of Bangkok Mass Transit Authority. Four bus numbers, including bus numbers 16, 63, 67 and 166, were randomly selected to investigate microbial air quality and to observe the effect of opening the exhaust ventilation fans in the bus. With each bus number, 9 to 10 air-conditioned buses (total, 39 air-conditioned buses) were included. In-bus air samples were collected at 5 points in each studied bus using the Millipore Air Tester. A total of 195 air samples were cultured for bacterial and fungal counts. The results reveal that the exhaust ventilation fans of 17 air-conditioned buses (43.6%) were opened to ventilate in-bus air during the cycle of the bus route. The means +/- SD of bacterial counts and fungal counts in the studied buses with opened exhaust ventilation fans (83.8 +/- 70.7 and 38.0 +/- 42.8 cfu/m3) were significantly lower than those in the studied buses without opened exhaust ventilation fans (199.6 +/- 138.8 and 294.1 +/- 178.7 cfu/m3), p < 0.0005. All the air samples collected from the studied buses with opened exhaust ventilation fans were at acceptable levels (< 500 cfu/m3) compared with 4.6% of the air samples collected from the studied buses without opened exhaust ventilation fans, which had high levels (> 500 cfu/m3). Of the studied buses with opened exhaust ventilation fans (17 buses), the bacterial and fungal counts after opening the exhaust ventilation fans (68.3 +/- 33.8 and 28.3 +/- 19.3 cfu/m3) were significantly lower than those before opening the exhaust ventilation fans (158.3 +/- 116.9 and 85.3 +/- 71.2 cfu/m3), p < 0.005.
机译:带空调的大众运输巴士的空气质量可能会影响公交驾驶员的健康。在曼谷地铁管理局第七公交区,通过打开公交车的排气通风风扇,在公交车司机的自愿参与下改善了公交车的空气质量。随机选择了四个公交车号,包括公交车号16、63、67和166,以调查微生物的空气质量并观察打开公交车上的排气通风风扇的效果。每个公共汽车号包括9到10辆空调公共汽车(总共39辆空调公共汽车)。使用Millipore空气测试仪在每辆研究的公共汽车中的5个点收集公共汽车内空气样本。共培养了195个空气样本,以进行细菌和真菌计数。结果表明,在公交路线的循环过程中,打开了17辆空调公交车的排气通风风扇(43.6%)以通风。打开排气通风风扇(83.8 +/- 70.7和38.0 +/- 42.8 cfu / m3)的研究公交车中细菌计数和真菌计数的平均值+/- SD显着低于未打开排气通风的研究公交车中的细菌计数和真菌计数平均值风扇(199.6 +/- 138.8和294.1 +/- 178.7 cfu / m3),p <0.0005。使用敞开的排气通风风扇从研究公交车中收集的所有空气样品均处于可接受的水平(<500 cfu / m3),相比之下,未使用敞开的排气通风风扇从研究公交车中收集的空气样品为4.6%(> 500 cfu / m3)。在已研究的排气扇已打开的公共汽车(17辆)中,打开排气扇(68.3 +/- 33.8和28.3 +/- 19.3 cfu / m3)后的细菌和真菌数量显着低于打开排气扇之前的细菌和真菌数量。通风风扇(158.3 +/- 116.9和85.3 +/- 71.2 cfu / m3),p <0.005。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号