Combination of pedCAT (R) for 3D Imaging in Standing Position With Pedography Shows No Statistical Correlation of Bone Position With Force/Pressure Distribution

机译:pedCAT(R)的3D站立姿势成像与影像学的结合显示,骨位置与力/压力分布没有统计相关性

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

pedCAT (R) (CurveBeam, Warrington, PA) is a technology for 3- dimensional (3D) imaging with full weightbearing that has been proved to exactly visualize the 3D bone position. For the present study, a customized pedography sensor (Pliance; Novel, Munich, Germany) was inserted into the pedCAT (R). The aim of our study was to analyze the correlation of the bone position and force/pressure distribution. A prospective consecutive study of 50 patients was performed, starting July 28, 2014. All patients underwent a pedCAT (R) scan and simultaneous pedography with full weightbearing in the standing position. The following parameters were measured on the pedCAT (R) image for the right foot by 3 different investigators 3 times: lateral talo-first metatarsal angle, calcaneal pitch angle, and minimum height of the fifth metatarsal base, second to fifth metatarsal heads, and medial sesamoid. From the pedography data, the following parameters were defined using the standardized software algorithm: midfoot contact area, maximum force of midfoot, maximum force of midfoot lateral, maximum force of entire foot, and maximum pressure of first to fifth metatarsal. The values of the corresponding pedCAT (R) and pedographic parameters were correlated (Pearson). The intra- and interobserver reliability of the pedCAT (R) measurements were sufficient (analysis of variance, p >.8 for each, power > 0.8). No sufficient correlation was found between the pedCAT (R) and pedographic parameters (r < 0.05 or r > -0.38). 3D bone position did not correlate with the force and pressure distribution under the foot sole during simultaneous pedCAT (R) scanning and pedography. Thus, the bone positions measured with pedCAT (R) do not allow conclusions about the force and pressure distribution. However, the static pedographic parameters also do not allow conclusions about the 3D bone position. one position and force/pressure distribution are important parameters for diagnostics, planning, and follow-up examinations in foot and ankle surgery. (C) 2016 by the American College of Foot and Ankle Surgeons. All rights reserved.
机译:pedCAT(R)(CurveBeam,沃灵顿,宾夕法尼亚州)是一种具有全负重的3D(3D)成像技术,已被证明可以精确地可视化3D骨骼位置。在本研究中,将定制的图形传感器(Pliance; Novel,慕尼黑,德国)插入了pedCAT(R)。我们研究的目的是分析骨骼位置与力/压力分布的相关性。自2014年7月28日开始,对50例患者进行了一项前瞻性连续研究。所有患者均接受pedCAT(R)扫描和同时进行的足弓训练,站立时完全负重。由3个不同的研究人员在pedCAT(R)图像上对3个不同的研究者测量了以下参数3次:侧向距骨-第一first骨角,跟骨俯仰角和第五meta骨基部,第二至第五meta骨头的最小高度,以及内侧芝麻。从脚印数据中,使用标准化软件算法定义以下参数:中足接触面积,中足最大力,中足外侧最大力,整只脚最大力以及第一到第五,骨的最大压力。相应的pedCAT(R)的值与摄影参数相关(Pearson)。 pedCAT(R)测量值在观察者内部和观察者之间的可靠性是足够的(方差分析,每个均p> 0.8,功效> 0.8)。在pedCAT(R)和摄影参数之间没有发现足够的相关性(r <0.05或r> -0.38)。在同时进行pedCAT(R)扫描和造影时,3D骨骼位置与脚底下的力和压力分布不相关。因此,用pedCAT(R)测量的骨骼位置无法得出有关力和压力分布的结论。但是,静态的摄影参数也无法得出有关3D骨骼位置的结论。一个位置和力/压力分布是脚踝手术诊断,计划和后续检查的重要参数。 (C)2016年,美国足踝外科医师学院。版权所有。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号