Noninvasive tracking of patient's head movements during computer-assisted intranasal microscopic surgery.

机译:在计算机辅助的鼻内镜显微手术中无创跟踪患者的头部运动。

获取原文
获取原文并翻译 | 示例
           

摘要

A noninvasive system designed for patient tracking during image-guided intranasal sinus surgery is described. It is based on optical digitizing with a custom-made registration and reference system, locatable surgical instruments, and a self-localizing operating microscope. Experimental and clinical results reveal a high degree of accuracy for the system. A mean spatial error of 0.82 +/- 0.31 mm was determined for repositioning of the reference system in a plastic model of the skull. For the positioning of the microscope, a mean error of 2.3 +/- 0.83 mm was calculated. Measurements of repositioning accuracy in 24 patients who received surgery for various sinus diseases had a mean spatial error of 1.56 +/- 0.76 mm. The 95% error interval for locating intranasal structures using the surgical instrument was 2.05 mm, and it was 4.92 mm using the microscope. These results suggest that the use of our noninvasive registration and reference system may be effective, accurate, and useful for noninvasive tracking of patient movements in computer-assisted intranasal surgery.
机译:描述了一种无创系统,其设计用于在图像引导的鼻内鼻窦手术期间跟踪患者。它基于光学数字化功能,其中包括定制的配准和参考系统,可定位的手术器械以及自动定位的手术显微镜。实验和临床结果表明该系统具有很高的准确性。确定在头骨的塑料模型中重新放置参考系统的平均空间误差为0.82 +/- 0.31 mm。对于显微镜的定位,计算出2.3±0.83mm的平均误差。测量接受各种鼻窦疾病手术的24例患者的重新定位准确性,其平均空间误差为1.56 +/- 0.76 mm。使用外科器械定位鼻内结构的95%误差间隔为2.05 mm,使用显微镜为4.92 mm。这些结果表明,在计算机辅助的鼻内手术中,我们的无创注册和参考系统的使用可能是有效,准确和对患者运动的无创跟踪有用的。