首页> 外文期刊>The Journal of trauma >Modified fluoroscopic imaging technique for the central screw placement in percutaneous screw fixation of scaphoid fracture.
【24h】

Modified fluoroscopic imaging technique for the central screw placement in percutaneous screw fixation of scaphoid fracture.

机译:改良的透视成像技术用于在舟状骨骨折的经皮螺钉固定中放置中心螺钉。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND:: The fluoroscopic imaging technique that has been used in the dorsal percutaneous screw fixation of scaphoid fracture was modified for more consistent central screw placement according to the different fracture locations. METHODS:: Eighteen scaphoids of the fresh-frozen cadaver were used. The computed tomographic data of scaphoid were reconstructed for 3D images. The reconstructed image was three dimensionally rotated to define the outlining images of scaphoid according to the three imaginary fracture lines (proximal 1/3, waist, distal 1/3). Two dimensional plain radiographic images were taken based on the 3D image to show the overlapping shapes of outer cortical lines of proximal and distal scaphoid. Under the fluoroscopic guidance, guide wire was inserted after the previously obtained 2D images. To verify the accuracy of fluoroscopic guidance for the fixation, the scaphoid was cut through each fracture plane and central position of each guide wire was analyzed. RESULTS:: For the proximal 1/3 fracture, the proximal cortical line was positioned on the radial side to the distal cortical line. For the waist fracture, two cortical shadows were eclipsed and for the distal 1/3, proximal cortical line was positioned ulna side to the distal cortical line. The cut surface analysis revealed statistically significant results of central guide wire placement for each fracture plane. CONCLUSIONS:: The fluoroscopic images should be individualized according to the fracture planes for more consistent and accurate central guide wire placement in the dorsal percutaneous screw fixation of scaphoid fracture.
机译:背景:荧光透视成像技术已被用于舟状骨骨折的背侧经皮螺钉固定术,以根据不同的骨折位置更一致地固定中心螺钉。方法:使用十八种新鲜冷冻尸体的舟骨。舟骨的计算机断层扫描数据被重建用于3D图像。根据三个假想断裂线(近端1/3,腰部,远端1/3)对重建的图像进行三维旋转,以定义舟骨的轮廓图像。基于3D图像拍摄了二维普通X射线摄影图像,以显示近端和远端舟骨外皮质线的重叠形状。在透视引导下,将导线插入先前获得的2D图像之后。为了验证透视引导下固定的准确性,将舟骨切开每个骨折平面,并分析每根导丝的中心位置。结果:对于近端1/3骨折,近端皮质线位于远端皮质线的径向侧。对于腰部骨折,两个皮层阴影被遮盖,对于远侧1/3,近侧皮层线位于远侧皮层线的尺骨侧。切割表面分析显示每个断裂平面的中心导丝放置的统计显着结果。结论:透视图像应根据骨折平面进行个性化,以便在舟状骨折的经皮背侧螺钉固定中更一致,更准确地将中央导丝放置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号