...
首页> 外文期刊>The Journal of Thoracic and Cardiovascular Surgery >Strut chordal-sparing mitral valve replacement preserves long-term left ventricular shape and function in pigs.
【24h】

Strut chordal-sparing mitral valve replacement preserves long-term left ventricular shape and function in pigs.

机译:撑杆保留脊索的二尖瓣置换术可长期保持猪的左心室形状和功能。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: Mitral valve replacement with preservation of the entire subvalvular apparatus entails superior postoperative left ventricular function compared with other techniques. However, this option is often not possible because of valve pathology. We hypothesized that preservation of only 4 mitral valve secondary ("strut") chordae would be functionally and geometrically equivalent to total valve preservation in the long-term setting. In a porcine mitral valve replacement model we investigated the long-term effects of 3 surgical techniques on left ventricular function and geometry: (1) total preservation of the native valve, (2) strut chordal preservation, and (3) total excision of the subvalvular apparatus. METHODS: Forty 60-kg pigs were randomized to 1 of the 3 techniques. Global and regional left ventricular function and dimensions were assessed with cardiovascular magnetic resonance and conductance catheter 90 days after mitral valve replacement. Groups were compared by multivariate analysis of variance. RESULTS: There was no overall difference between groups 1 and 2. Group 3 animals had (1) greater base-apex diastolic and systolic lengths, and smaller short-axis diameters, and (2) lower sphericity indices, and greater base-apex and short-axis fractional shortening than groups 1 and 2. Regional analysis showed slimming and elongation to occur primarily in the basal left ventricular segments. Left ventricular contractility and hemodynamic parameters did not differ between groups. CONCLUSIONS: Strut chordal preservation was equivalent to total valve preservation during mitral valve replacement, whereas total chordal resection caused significant left ventricular slimming with compensatory increases in fractional shortening. Therefore, to preserve left ventricular geometry, special attention must be paid to maintain the valvular-ventricular continuity through the strut chordae during mitral valve replacement. This concept may have important therapeutic implications for chordal-sparing mitral valve replacement.
机译:目的:与其他技术相比,二尖瓣置换术能保留整个瓣膜下装置,因此术后左心室功能优越。但是,由于瓣膜病变,通常无法使用该选项。我们假设,在长期设置中,仅保留4个二尖瓣副(“支杆”)腱索在功能上和几何上均等同于总瓣膜的保留。在猪二尖瓣置换模型中,我们研究了3种外科手术技术对左心室功能和几何形状的长期影响:(1)完全保留天然瓣膜,(2)撑杆保持弦,以及(3)完全切除瓣膜下装置。方法:将40头60公斤猪随机分配到3种技术中的1种。二尖瓣置换术后90天,通过心血管磁共振和电导导管评估整体和局部左心室功能和大小。通过方差的多变量分析比较各组。结果:第1组和第2组之间没有总体差异。第3组动物具有(1)根尖舒张期和收缩期较长,短轴直径较小,(2)球形度较低,根尖期和收缩期较大。短轴分数比第1组和第2组短。区域分析显示,减肥和伸长主要发生在左室基底基底节段。各组左心室收缩力和血流动力学参数无差异。结论:在二尖瓣置换过程中,撑杆的弦保留与总瓣的保留相当,而全弦切除导致左心室显着纤细,而分数缩短的补偿性增加。因此,为了保持左心室的几何形状,必须特别注意在二尖瓣置换过程中通过支撑杆的弦保持瓣膜心室的连续性。这个概念可能对保留弦的二尖瓣置换术有重要的治疗意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号