首页> 外文期刊>The Journal of Thoracic and Cardiovascular Surgery >The snuffbox technique: a reliable color Doppler method to assess hand circulation.
【24h】

The snuffbox technique: a reliable color Doppler method to assess hand circulation.

机译:鼻烟盒技术:一种可靠的彩色多普勒方法来评估手部血液循环。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: Although the Allen test is crude and subjective, an objective color Doppler method has yet to be established in the assessment of hand circulation before radial artery harvesting. Doppler studies so far have neglected the Doppler principle that the insonation angles should be less than 30 degrees and have not been compared with any standard except the crude Allen test. We therefore introduced the snuffbox technique, measuring the radial artery at the anatomic snuffbox, which is the most distal area after harvesting. Color Doppler methods were compared with the stump pressure as a criterion standard. METHODS: Maximal flow velocity and Doppler angles of the snuffbox, palmar artery, and ulnar artery were measured in 20 hands before and after radial artery harvesting. Stump pressure was measured during surgery. RESULTS: Maximal flow velocity in the snuffbox decreased with radial artery compression and after radial artery harvesting. All the flow patterns in the snuffbox technique showed simultaneous reversal. Maximal flow velocity in the ulnar artery increased with radial artery compression and after radial artery harvesting. Maximal flow velocity in the palmar artery did not change significantly with radial artery compression or after radial artery harvesting. Doppler angles were 20.9 degrees +/- 6.0 degrees in the radial artery of the snuffbox, 82.5 degrees +/- 6.1 degrees at the palmar artery, and 81.0 degrees +/- 7.6 degrees at the ulnar artery. The changes in the snuffbox technique were highly correlated with the stump pressure ratio (P <.001). CONCLUSIONS: Among various color Doppler methods, the snuffbox technique was precise and reliable.
机译:目的:尽管艾伦(Allen)检验是粗略且主观的,但尚无客观的彩色多普勒方法用于评估radial动脉采集前的手部循环。迄今为止,多普勒研究忽略了多普勒原理,即声入射角应小于30度,并且除粗制艾伦试验外,未与任何标准进行比较。因此,我们引入了鼻烟盒技术,在解剖鼻烟盒处测量the动脉,这是收获后最远端的区域。将彩色多普勒方法与残端压力作为标准标准进行了比较。方法:测量radial动脉采集前后20只手的鼻烟盒,掌动脉和尺动脉的最大流速和多普勒角度。在手术期间测量残端压力。结果:鼻radial中的最大流速随radial动脉压缩和radial动脉采集后降低。鼻烟盒技术中的所有流动模式均显示出同时逆转。尺动脉的最大流速随flow动脉压缩和radial动脉采集后的增加而增加。随着radial动脉压缩或or动脉采集后,掌动脉中的最大流速没有明显变化。在鼻烟盒的radial动脉中,多普勒角为20.9度+/- 6.0度,在掌动脉中为82.5度+/- 6.1度,在尺骨动脉中为81.0度+/- 7.6度。鼻烟盒技术的变化与树桩压力比高度相关(P <.001)。结论:在各种彩色多普勒方法中,鼻烟盒技术是精确和可靠的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号