首页> 外文期刊>The Journal of toxicological sciences >Inter-laboratory study of short time exposure (STE) test for predicting eye irritation potential of chemicals and correspondence to globally harmonized system (GHS) classification.
【24h】

Inter-laboratory study of short time exposure (STE) test for predicting eye irritation potential of chemicals and correspondence to globally harmonized system (GHS) classification.

机译:实验室间的短时暴露(STE)测试,用于预测化学品的眼睛刺激潜能,并与全球统一系统(GHS)分类相对应。

获取原文
获取原文并翻译 | 示例
           

摘要

Short time exposure (STE) test using rabbit corneal cell line (SIRC) cells was developed as an alternative eye irritation test. STE test uses relative viability as the endpoint after cells are exposed to the test material at constant concentrations for 5 min. In this inter-laboratory study with 3 laboratories, 44 chemicals with a wide range of classes were evaluated for the transferability, between-lab reproducibility and predictive capacity of the STE test as an alternative eye irritation test. Globally harmonized system (GHS) classification based on Draize eye irritation test data was used as the comparative in vivo data. Transferability was assessed using standard chemicals (sodium lauryl sulfate, calcium thioglycolate, and Tween 80) and the coefficient variations (CVs) of relative viabilities between 3 labs were less than 0.13. The irritation category (Irritant or Non irritant) at each test concentration (5% and 0.05%) in STE test was the same in 3 laboratories for all 44 tested chemicals. The predictive capacity irritation category classification between STE test and GHS were compared, and a good correlation was confirmed (accuracy was 90.9% at all laboratories). In addition, the STE rankings of 1, 2, and 3 classified by the prediction model (PM) based on the relative viability at two concentrations (5% and 0.05%) were highly correlated with the GHS ranks of non-irritant, category 1, and category 2, respectively (accuracy was 75.0% at all laboratories). These results suggest that the STE test possessed easy transferability, reproducibility, good predictive performance.
机译:已开发出使用兔角膜细胞系(SIRC)细胞的短时暴露(STE)测试作为替代性眼刺激测试。在将细胞以恒定浓度暴露于测试材料5分钟后,STE测试使用相对生存力作为终点。在这个由3个实验室组成的实验室间研究中,对STE测试(作为替代性眼刺激测试)的可转移性,实验室间再现性和预测能力进行了评估,评估了44种不同类别的化学品。基于Draize眼睛刺激性测试数据的全球统一系统(GHS)分类用作体内比较数据。使用标准化学药品(十二烷基硫酸钠,硫代乙醇酸钙和Tween 80)评估了可转移性,三个实验室之间的相对生存力的系数变异(CV)小于0.13。在3个实验室中,对于44种被测化学物质,STE测试中每种测试浓度(5%和0.05%)时的刺激类别(刺激性或非刺激性)均相同。比较了STE测试和GHS之间的预测能力刺激类别分类,并确认了良好的相关性(所有实验室的准确性均为90.9%)。此外,根据预测模型(PM)在两种浓度(5%和0.05%)下的相对生存力,通过预测模型(PM)分类的STE等级分别与1类非刺激性的GHS等级高度相关和2类(所有实验室的准确性均为75.0%)。这些结果表明,STE测试具有易转移性,可重复性和良好的预测性能。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号