The effectiveness of ethanol locks for prevention of central venous catheter (CVC)-associated bloodstream infection (CLABSI) in adult haematology patients has not been thoroughly evaluated. This study aimed to compare prospectively heparinized saline with 70% ethanol locks using 2. h dwell time in patients with tunnelled CVCs. In saline (N=43) and ethanol (N=42) groups, CLABSI rates were 6.0 [95% confidence interval (CI): 3.4-9.8] and 4.1 (95% CI: 1.9-7.7) per 1000 CVC days, respectively (P=0.42). In the ethanol group, two exit-site infections and one tunnel/pocket infection were observed. Reduction in device-associated infection was not achieved with prophylactic 70% ethanol locks in patients with haematological malignancy and tunnelled CVCs.
机译:尚未完全评估乙醇锁在成人血液学患者中预防中心静脉导管(CVC)相关的血流感染(CLABSI)的有效性。这项研究的目的是比较使用隧道CVC的患者在2. h停留时间内的前瞻性肝素化盐水与70%乙醇锁的比较。在盐水(N = 43)和乙醇(N = 42)组中,每1000 CVC天CLABSI发生率分别为6.0 [95%置信区间(CI):3.4-9.8]和4.1(95%CI:1.9-7.7)。 (P = 0.42)。在乙醇组中,观察到两个出口部位感染和一个隧道/口袋感染。在血液系统恶性肿瘤和隧道性CVC的患者中,预防性使用70%的乙醇锁无法减少器械相关感染。