With the detection of prions in specific tissues in variant and sporadic Creutzfeldt-Jakob diseases, efficient decontamination for human transmissible spongiform encephalopathy (TSE) agents, that is compatible with medical equipment, has become a major issue. We previously described the cleavage of prions on exposure to copper (Cu) and hydrogen peroxide (H(2)O(2)) and have used this property to develop efficient prion decontamination processes. To validate this approach, in-vitro assays on genuine human and animal prions using both brain homogenates and steel wires to mimic contamination of medical equipment were conducted. In-vivo experiments using steel wire in the hamster 263 K model were then used to evaluate the effect on prion infectivity. Assays on classical pathogens following international norms completed these prion experiments. In-vitro data confirmed the full decontamination efficacy of H(2)O(2)/Cu on different TSE strains. Combination of Cu with peracetic acid, used for endoscope disinfection, also revealed improved prion decontamination. Animal assay demonstrated efficacy on TSE infectivity of H(2)O(2)/Cu alone or in combination with detergents (reduction factor > or =5.25 log(10)). Assays on classical pathogens confirmed the disinfection properties of the different processes. Taken together, these new disinfection processes are efficient for both conventional and prion infectious agents and are, compatible with thermosensitive medical equipment. They can be adapted to hospitals' and practitioners' routine use, and they present reduced risks for the environment and for healthcare professionals.
机译:随着变种和散发性克雅氏病在特定组织中pr病毒的检测,与医疗设备兼容的人类可传播海绵状脑病(TSE)药剂的有效净化已成为一个主要问题。我们先前描述了暴露于铜(Cu)和过氧化氢(H(2)O(2))时病毒的裂解,并已使用此性质来开发有效的病毒去污工艺。为了验证这种方法,在体外使用人脑匀浆和钢丝模拟医疗设备的污染,对真正的人和动物病毒进行了体外测定。然后使用钢丝在仓鼠263 K模型中进行体内实验,以评估其对病毒感染性的影响。根据国际规范对经典病原体的测定完成了这些病毒实验。体外数据证实了H(2)O(2)/ Cu对不同TSE菌株的完全去污效力。用于内窥镜消毒的铜与过氧乙酸的组合也显示出改善的病毒去污能力。动物实验证明单独或与去污剂结合对H(2)O(2)/ Cu的TSE感染性有效(还原因子>或= 5.25 log(10))。对经典病原体的测定证实了不同过程的消毒特性。综上所述,这些新的消毒过程对常规和病毒感染剂均有效,并且与热敏医疗设备兼容。它们可以适应医院和从业人员的常规使用,并且降低了环境和医护人员的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号