Computed tomography based computer simulation studies were made on fifty consecutive patients with osteoarthritis scheduled for TKA. Proximal tibial cutting was simulated with the cutting guide placed at different rotational errors (- 10°, 0°, 10° and 20° of internal rotation) and different distances (4. cm and 8. cm) between the alignment rod and the bone. Only ten degrees of rotation error with 8. cm of distance resulted in over 3° of varus or valgus tibial cut. Our study demonstrated that rotational mismatch between the proximal and distal part of the tibia should be avoided and the distance between the alignment rod and the bone should be as short as possible to achieve proper tibial alignment.
机译:基于计算机断层扫描的计算机模拟研究是针对计划进行TKA的50例连续性骨关节炎患者进行的。使用切割导向器模拟胫骨近端切割,将其放置在不同的旋转误差(内旋转为-10°,0°,10°和20°)和对齐杆与骨骼之间的不同距离(4. cm和8. cm)的情况下。只有十度的旋转误差和8 cm的距离会导致超过3°的内翻或外翻胫骨切口。我们的研究表明,应避免胫骨近端和远端之间的旋转不匹配,并且对准杆和骨骼之间的距离应尽可能短,以实现正确的胫骨对准。