One hundred four hips in 107 patients undergoing revision arthroplasty of the hip were identified at risk of dislocation and treated with the constrained cup. Radiostereometric analysis was performed to assess prosthesis migration. Mean follow-up was 3.0 years (range, 2.0-4.8). At last review, 19 patients had died and 6 were lost to follow-up. There were 5 revisions for cup loosening and a further 4 with radiographic evidence of loosening. There were 3 dislocations and 3 dissociations in 5 patients. Radiostereometric analysis demonstrated that cup migration at 24 months was up to 0.82 mm of translation and 1.58 degrees of rotation. Our results confirm that the constrained acetabular component is a highly effective option for the treatment for patients with instability of the hip. The aseptic loosening rate was higher than previously reported.
机译:107例接受髋关节置换术的患者中的一百四十个髋关节被确定有脱位的风险,并用约束杯进行治疗。进行放射立体分析以评估假体的迁移。平均随访时间为3.0年(范围2.0-4.8)。在最近的复查中,有19例患者死亡,另有6例失访。杯子松动有5个修订版本,还有4个带有松动影像学证据的版本。 5名患者中有3个脱位和3个分离。放射立体分析表明,杯在24个月时的移动最大为平移0.82 mm,旋转度为1.58。我们的结果证实,受约束的髋臼组件是治疗髋关节不稳定患者的高效选择。无菌松动率高于以前的报告。