首页> 外文期刊>The Journal of arthroplasty >A double offset broach handle for preparation of the femoral cavity in minimally invasive direct anterior total hip arthroplasty.
【24h】

A double offset broach handle for preparation of the femoral cavity in minimally invasive direct anterior total hip arthroplasty.

机译:双偏置拉刀手柄,用于在微创直接前路全髋关节置换术中准备股骨腔。

获取原文
获取原文并翻译 | 示例
       

摘要

A direct anterior approach is in use for minimally invasive total hip arthroplasty. This approach uses an intermuscular and internerval plane between the sartorius, rectus femoris, and tensor fasciae latae. Although preparation of the acetabulum and implantation of the acetabular component is an easy task with the available instruments, preparation of the femoral canal through this single incision is more demanding. Instrumentation of the femur involves careful preparation of the dorsal capsule, positioning of the operated leg, and leverage of the femur. A broach handle with lateral and anterior offset for the direct anterior approach has been developed to reduce the need for leverage of the proximal femur for preparation of the cavity.
机译:直接前路入路用于微创全髋关节置换术。这种方法使用了肌肉的肌间和神经间的平面,在肌缝,股直肌和筋膜张肌之间。尽管准备髋臼和植入髋臼组件是使用现有器械的一项容易的任务,但通过该单个切口准备股骨管的要求更高。股骨的器械检查包括仔细准备背囊,操作腿的位置以及股骨的杠杆作用。已经开发了用于直接前路入路的具有横向和前向偏移的拉刀手柄,以减少对准备股骨所需的近端股骨的杠杆作用。