首页> 外文期刊>The Journal of arthroplasty >Validation of 11 kGy as a radiation sterilization dose for frozen bone allografts.
【24h】

Validation of 11 kGy as a radiation sterilization dose for frozen bone allografts.

机译:验证11 kGy作为同种异体冷冻骨的放射灭菌剂量。

获取原文
获取原文并翻译 | 示例
           

摘要

A radiation sterilization dose (RSD) of 25 kGy is deleterious to bone allografts. This study aimed to establish a lower RSD for bone allografts using method 1 of International Standard Organisation 11137.2:2006. This provides a database to select an RSD corresponding to an allograft's bioburden, given that the bioburden's gamma resistance is equal to or less than the standard. This can be verified by irradiating 100 allografts at a dose selected to provide a sterility assurance level of 10(-2). The bioburden of our allografts was 0, which prescribed a verification dose of 1.3 kGy. After irradiating 100 allografts, sterility tests returned no positive cultures. We therefore validated an RSD of 11 kGy for allografts with that bioburden. According to the standard, this RSD provides a sterility assurance level of 10(-6) for bone allografts.
机译:25 kGy的辐射灭菌剂量(RSD)对同种异体骨有害。这项研究旨在使用国际标准组织11137.2:2006的方法1为同种异体骨建立较低的RSD。假定生物负载的伽玛抵抗力等于或小于标准值,这将提供一个数据库来选择与同种异体移植生物负载相对应的RSD。这可以通过以选择的剂量提供100(-2)无菌保证水平照射100个同种异体移植物来验证。同种异体移植的生物负荷为0,规定的验证剂量为1.3 kGy。辐照了100个同种异体移植物后,无菌测试未返回阳性培养物。因此,我们验证了具有该生物负荷的同种异体移植的RSD为11 kGy。根据该标准,该RSD为同种异体骨提供的无菌保证水平为10(-6)。