首页> 外文OA文献 >Validation of 11 kGy as a Radiation Sterilisation Dose for Frozen Bone Allografts
【2h】

Validation of 11 kGy as a Radiation Sterilisation Dose for Frozen Bone Allografts

机译:验证11 kGy作为冷冻同种异体骨的放射灭菌剂量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A radiation sterilization dose (RSD) of 25 kGy is deleterious to bone allografts. This study aimed to establish a lower RSD for bone allografts using method 1 of International Standard Organisation 11137.2:2006. This provides a database to select an RSD corresponding to an allograft's bioburden, given that the bioburden's gamma resistance is equal to or less than the standard. This can be verified by irradiating 100 allografts at a dose selected to provide a sterility assurance level of 10-2. The bioburden of our allografts was 0, which prescribed a verification dose of 1.3 kGy. After irradiating 100 llografts, sterility tests returned no positive cultures. We therefore validated an RSD of 11 kGy for allografts with that bioburden. According to the standard, this RSD provides a sterility assurance level of 10-6 for bone allografts.
机译:25 kGy的辐射灭菌剂量(RSD)对同种异体骨有害。这项研究旨在使用国际标准组织11137.2:2006的方法1为骨同种异体移植建立较低的RSD。假定生物负载的伽玛抵抗力等于或小于标准值,这将提供一个数据库来选择与同种异体移植生物负载相对应的RSD。这可以通过以选定的提供10-2无菌保证水平的剂量照射100个同种异体移植物来验证。同种异体移植的生物负荷为0,这规定了1.3 kGy的验证剂量。辐照了100次同种异体移植后,无菌测试未返回阳性培养物。因此,我们验证了具有该生物负荷的同种异体移植的RSD为11 kGy。根据该标准,该RSD为同种异体骨提供的无菌保证水平为10-6。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号