We evaluated the accuracy and clinical usefulness of preoperative templating in 109 cementless total hip arthroplasties. The size of the prosthesis was exactly predicted in 46 (42.2%) acetabular and 75 (68.8%) femoral components. The accuracy increased to greater than 90% if the prosthesis size was within 1 or 2 sizes (above or below) for femoral component and acetabular components, respectively. Having a contralateral total hip arthroplasty as a guide for preoperative templating was associated with greater accuracy in predicting the femoral component size only. Eighty-eight percent of the acetabular components were oriented inside the presumed safe range for inclination; 42% of the acetabular components were in the presumed safe range of anteversion. The mean postoperative leg length discrepancy was 0.9 +/- 6.8 mm; 93.5% had a discrepancy within 10 mm.
机译:我们评估了109例非骨水泥全髋关节置换术中术前模板的准确性和临床实用性。假体的大小在髋臼的46个(42.2%)和股骨的75个(68.8%)中得到了精确预测。如果假体尺寸在股骨组件和髋臼组件的大小分别在1或2个大小(上下左右)以内,则准确性提高到90%以上。以对侧全髋关节置换术作为术前模板制作的指南与仅预测股骨组件尺寸的准确性更高。 88%的髋臼组件的方向在假定的倾斜安全范围内; 42%的髋臼组件处于假定的前倾安全范围内。术后平均腿长差异为0.9 +/- 6.8毫米; 93.5%的误差在10毫米以内。