首页> 外文期刊>The Journal of hand surgery, European volume >A knotless bidirectional-barbed tendon repair is inferior to conventional 4-strand repairs in cyclic loading
【24h】

A knotless bidirectional-barbed tendon repair is inferior to conventional 4-strand repairs in cyclic loading

机译:在循环载荷下,无节双向刺筋修复效果不如传统的四股修复方法

获取原文
获取原文并翻译 | 示例
           

摘要

We divided 21 flexor digitorum profundus tendons in the index, middle and ring fingers in seven cadaver hands into three groups. The tendons were cut in zone 2 and repaired using a 4-strand cruciate core suture repair with one of the following three materials in each group: (1) a knotless repair with a 2-0 bidirectional-barbed suture, which has similar tensile strength as a 4-0 non-barbed suture used in the other two groups; (2) a knotted locking repair with a non-barbed 4-0 conventional suture; and (3) a non-locking repair with a non-barbed 4-0 knotless suture. The repaired fingers were cyclically loaded through a simulated active range of motion to a 5N load. We monitored and recorded the gap sizes at regular intervals during the test. The 2-0 bidirectional-barbed suture group and non-barbed suture groups developed gaps of 2.2mm after 10 cycles and 2.4mm after 20 cycles, respectively. Over 1000 cycles, the mean gaps were 3.2mm in the 4-0 conventional suture group and 9.1mm in the 2-0 bidirectional-barbed group. The tendons in the 2-0 bidirectional-barbed group gapped earlier, with statistically significant differences compared with those in the locking repair with a non-barbed 4-0 knotless suture group. The repair strength of the barbed suture technique was inferior to the cruciate repairs using a conventional 4-0 non-barbed suture tested in this cyclic-loading model. Level of evidence: Level V
机译:我们将七只尸体手的食指,中指和无名指中的21指前屈肌腱分为三组。将肌腱在第2区切开,并使用四股十字形芯缝合线修复,每组使用以下三种材料之一进行修复:(1)用2-0双向倒刺缝合进行无结修复,其抗张强度相似作为其他两组使用的4-0无刺缝合线; (2)用无刺的4-0常规缝合线进行打结的锁定修复; (3)使用无倒刺的4-0无结缝线进行的非锁定修复。修复后的手指通过模拟的有效运动范围周期性地加载到5N负载。在测试过程中,我们定期监控并记录间隙尺寸。 2-0双向倒刺缝线组和非倒刺缝线组在10个循环后分别出现2.2mm和20个循环后出现2.4mm的缝隙。在1000次循环中,常规缝线4-0组的平均间隙为3.2mm,双向针刺组2-0的平均间隙为9.1mm。 2-0双向倒刺组的肌腱间隙较早,与无倒刺的4-0无结缝合线组的锁定修复相比,具有统计学上的显着差异。带刺缝合技术的修复强度不及使用在该循环加载模型中测试的常规4-0非带刺缝合技术进行的十字形修复。证据级别:V级

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号