Wireless Vital Sign Monitoring in Pregnant Women: A Functionality and Acceptability Study

机译:孕妇无线生命体征监测:功能和可接受性研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective: To test the functionality and acceptability of a wireless vital sign monitor in an inpatient obstetric unit. Materials and Methods: Pregnant women at a U.S. tertiary-care hospital wore a wireless vital sign sensor that captures heart rate, respiratory rate, and temperature. Measurements were compared with vital signs obtained by standard devices. We defined continuous capture of vital signs for 30 min with wireless data transfer to a central monitor as functional success. Acceptability was assessed per the pregnant women and nurses observing the device. Bland-Altman plots were constructed to assess agreement between the wireless sensor and standard measurements. Results: Thirty of 32 enrolled pregnant women had successful monitoring; 2 cases were stopped early for non-study-related reasons. Comparing wireless sensor and standard measurements, the mean difference (limits of agreement) values at the 25th and 75th percentiles were 1.6 (+/- 13.2) and 4.2 (+/- 18.6) heartbeats/min, 4.2 (+/- 6.1) and 0.7 (+/- 5.4) respirations/min, and 0.02 degrees C (+/- 1.5) and 0.5 degrees C (+/- 1.8), respectively. Most pregnant women found the device comfortable, likeable, and useful (78%, 81%, and 97%, respectively); 80% of nurses found the monitor easy to use, and 84% would recommend it to a patient. Conclusions: We successfully obtained maternal vital signs using a simple wireless monitor with high acceptability. Well-validated monitors of this nature could significantly alleviate the human resource burden of monitoring during labor and confer greatly desired mobility to laboring pregnant women, although incorporation of blood pressure monitoring will be critical.
机译:目的:测试住院产科设备中无线生命体征监护仪的功能和可接受性。材料和方法:美国三级医院的孕妇戴着无线生命体征传感器,可捕获心率,呼吸频率和体温。将测量结果与通过标准设备获得的生命体征进行比较。我们将连续30分钟的生命体征定义为通过无线数据传输到中央监视器来实现功能成功。根据观察该装置的孕妇和护士评估可接受性。构造Bland-Altman图以评估无线传感器和标准测量之间的一致性。结果:32名登记的孕妇中有30名成功进行了监测。 2例因非研究相关原因而提前停止。比较无线传感器和标准测量结果,第25和第75个百分位数的平均差(一致性极限)值为1.6(+/- 13.2)和4.2(+/- 18.6)/min、4.2(+/- 6.1)/ min。每分钟0.7(+/- 5.4)次呼吸,以及0.02摄氏度(+/- 1.5)和0.5摄氏度(+/- 1.8)。大多数孕妇发现该设备舒适,令人喜爱和有用(分别为78%,81%和97%); 80%的护士发现监护仪易于使用,而84%的护士会推荐给患者。结论:我们使用具有高接受度的简单无线监视器成功获得了孕妇生命体征。经过充分验证的这种性质的监护仪可以极大地减轻分娩过程中监护的人力资源负担,并赋予正在工作的孕妇以极大的期望流动性,尽管合并血压监护将至关重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号