High-resolution fluorodeoxyglucose positron emission tomography with compression ('positron emission mammography') is highly accurate in depicting primary breast cancer.

机译:带有压缩的高分辨率氟脱氧葡萄糖正电子发射断层扫描(“正电子发射乳房X线照相”)在描绘原发性乳腺癌中非常准确。

获取原文
获取原文并翻译 | 示例
           

摘要

We sought to prospectively assess the diagnostic performance of a high-resolution positron emission tomography (PET) scanner using mild breast compression (positron emission mammography [PEM]). Data were collected on concomitant medical conditions to assess potential confounding factors. At four centers, 94 consecutive women with known breast cancer or suspicious breast lesions received 18F-fluorodeoxyglucose (FDG) intravenously, followed by PEM scans. Readers were provided clinical histories and x-ray mammograms (when available). After excluding inevaluable cases and two cases of lymphoma, PEM readings were correlated with histopathology for 92 lesions in 77 women: 77 index lesions (42 malignant), 3 ipsilateral lesions (3 malignant), and 12 contralateral lesions (3 malignant). Of 48 cancers, 16 (33%) were clinically evident; 11 (23%) were ductal carcinoma in situ (DCIS), and 37 (77%) were invasive (30 ductal, 4 lobular, and 3 mixed; median size 21 mm). PEM depicted 10 of 11 (91%) DCIS and 33 of 37 (89%) invasive cancers. PEM was positive in 1 of 2 T1a tumors, 4 of 6 T1b tumors, 7 of 7 T1c tumors, and 4 of 4 cases where tumor size was not available (e.g., no surgical follow-up). PEM sensitivity for detecting cancer was 90%, specificity 86%, positive predictive value (PPV) 88%, negative predictive value (NPV) 88%, accuracy 88%, and area under the receiver-operating characteristic curve (Az) 0.918. In three patients, cancer foci were identified only on PEM, significantly changing patient management. Excluding eight diabetic subjects and eight subjects whose lesions were characterized as clearly benign with conventional imaging, PEM sensitivity was 91%, specificity 93%, PPV 95%, NPV 88%, accuracy 92%, and Az 0.949 when interpreted with mammographic and clinical findings. FDG PEM has high diagnostic accuracy for breast lesions, including DCIS.
机译:我们试图前瞻性评估使用轻度乳房压迫的高分辨率正电子发射断层扫描(PET)扫描仪(PET)的诊断性能。收集有关伴随疾病的数据,以评估潜在的混杂因素。在四个中心,连续94名患有已知乳腺癌或可疑乳腺病变的妇女接受了静脉注射18F-氟脱氧葡萄糖(FDG),然后进行PEM扫描。向读者提供了临床病史和X线乳房X线照片(如果有)。在排除了无价值的病例和2例淋巴瘤之后,PEM读数与77位女性的92个病变的组织病理学相关:77个指数病变(42个恶性),3个同侧病变(3个恶性)和12个对侧病变(3个恶性)。在48种癌症中,有16种(33%)在临床上是明显的; 11例(23%)为导管原位癌(DCIS),37例(77%)为浸润性(30导管,4小叶和3混合;中位大小为21 mm)。 PEM描述了11种DCIS中的10种(占91%)和37种浸润性癌症(占89%)中的33种。 PEM在2例T1a肿瘤中的1例,6例T1b肿瘤中的4例,7例T1c肿瘤中的7例以及4例肿瘤大小不可用的例中4例(例如,没有手术随访)。 PEM检测癌症的敏感性为90%,特异性为86%,阳性预测值(PPV)为88%,阴性预测值(NPV)为88%,准确性为88%,并且受试者工作特征曲线下的面积(Az)为0.918。在三名患者中,仅在PEM上发现了癌灶,从而大大改变了患者管理。排除8位糖尿病患者和8位常规影像学检查明确表现为良性病变的患者后,经乳房X线照片和临床检查发现,PEM敏感性为91%,特异性为93%,PPV为95%,NPV为88%,准确性为92%,Az为0.949。 。 FDG PEM对包括DCIS在内的乳腺病变具有很高的诊断准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号