首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Sensitive fluorimetric determination of formaldehyde by the co-quenching effect of formaldehyde and sulfite on the fluorescence of tetra-substituted amino aluminium phthalocyanine
【24h】

Sensitive fluorimetric determination of formaldehyde by the co-quenching effect of formaldehyde and sulfite on the fluorescence of tetra-substituted amino aluminium phthalocyanine

机译:甲醛与亚硫酸盐共猝灭对四取代氨基铝酞菁荧光的灵敏荧光法测定甲醛

获取原文
获取原文并翻译 | 示例
           

摘要

A novel and sensitive fluorimetric method was developed for the determination of formaldehyde based on the co-quenching effect of formaldehyde and sulfite on the fluorescence of tetra-substituted amino aluminium phthalocyanine. Formaldehyde in the concentration range 0.040-1.19 #mu#g ml~(-1) can be determined with a limit of detection of 7.5 ng ml~(-1). The relative standard deviation for nine replicate measurements of 80.0 ng ml~(-1) formaldehyde is 1.8%. The method was applied to the analysis of real samples with satisfactory results.
机译:基于甲醛和亚硫酸盐对四取代氨基铝酞菁荧光的共猝灭作用,开发了一种新颖,灵敏的荧光法测定甲醛。可以测定浓度范围为0.040-1.19#mu#g ml〜(-1)的甲醛,检出限为7.5 ng ml〜(-1)。 9次重复测量的80.0 ng ml〜(-1)甲醛的相对标准偏差为1.8%。该方法用于实际样品的分析,结果令人满意。