首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >A non-enzymatic sensor for hydrogen peroxide based on polyaniline, multiwalled carbon nanotubes and gold nanoparticles modified Au electrode
【24h】

A non-enzymatic sensor for hydrogen peroxide based on polyaniline, multiwalled carbon nanotubes and gold nanoparticles modified Au electrode

机译:基于聚苯胺,多壁碳纳米管和金纳米粒子修饰的金电极的双氧水非酶传感器

获取原文
获取原文并翻译 | 示例

摘要

We describe the construction of a polyaniline (PANI), multiwalled carbon nanotubes (MWCNTs) and gold nanoparticles (AuNPs) modified Au electrode for determination of hydrogen peroxide without using peroxidase (HRP). The AuNPs/MWCNT/PANI composite film deposited on Au electrode was characterized by Scanning Electron Microscopy (SEM) and electrochemical methods. Cyclic voltammetric (CV) studies of the electrode at different stages of construction demonstrated that the modified electrode had enhanced electrochemical oxidation of H_2O_2, which offers a number of attractive features to develop amperometric sensors based on split of H_2O_2. The amperometric response to H_2O_2 showed a linear relationship in the range from 3.0 μM to 600.0 μM with a detection limit of 0.3 μM (S/N = 3) and with high sensitivity of 3.3 mA μM~(-1). The sensor gave accurate and satisfactory results, when employed for determination of H_2O_2 in milk and urine.
机译:我们描述了聚苯胺(PANI),多壁碳纳米管(MWCNT)和金纳米颗粒(AuNPs)修饰的Au电极的构建,无需使用过氧化物酶(HRP)即可测定过氧化氢。用扫描电子显微镜(SEM)和电化学方法对沉积在Au电极上的AuNPs / MWCNT / PANI复合膜进行了表征。对电极在不同构造阶段的循环伏安(CV)研究表明,改性电极增强了H_2O_2的电化学氧化,这为基于H_2O_2的分离开发安培传感器提供了许多诱人的功能。对H_2O_2的安培响应在3.0μM至600.0μM范围内呈线性关系,检测极限为0.3μM(S / N = 3),高灵敏度为3.3 mAμM〜(-1)。该传感器用于牛奶和尿液中H_2O_2的测定,结果准确,令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号