首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Determination of bismuth in biological samples using on-line flow-injection microwave-assisted mineralization and precipitation/dissolution for electrothermal atomic absorption spectrometry
【24h】

Determination of bismuth in biological samples using on-line flow-injection microwave-assisted mineralization and precipitation/dissolution for electrothermal atomic absorption spectrometry

机译:在线流动注射微波辅助矿化和电热原子吸收光谱仪的沉淀/溶解法测定生物样品中的铋

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

An on-line automated flow injection system with microwave-assisted sample digestion for the electrothermal atomic absorption spectrometric determination of bismuth in biological materials is described. After the exposure of the sample to microwave radiation, the analyte was subject to a precipitation/dissolution process. Bismuth was precipitated with the stannite ion in basic medium and collected on the walls of a knotted coil, while the other matrix components flowed downstream to waste. The precipitate was dissolved with nitric acid and a sub-sample was collected in a capillary of a sampling arm assembly, to introduce 20 #mu#l volumes into the graphite tube by means of positive displacement with air through a time-based injector. The analytical figures of merit were first evaluated by filling the sampling arm with a standard solution of bismuth and thereafter injecting aliquots of this solution into the atomizer. The calibration graph was linear from the detection limit (8 pg) to 1.2 ng of bismuth. The sensitivity was of 26.8 #mu#g 1~(-1) for 0.2 A-s and the characteristic mass (m_o) was of 11.8 pg/0.0044 A-s. The precision of the method, evaluated by replicate analyses of solutions containing 20 and 200 pg of bismuth, were 5.5 and 3.0% (n=10), respectively. When solutions were introduced in the flow system here described, the calibration graph was linear in the range 0.04-6.0 #mu#g 1~(-1), which means that a preconcentration factor of 10 was obtained for bismuth. The precision slightly deteriorated, e.g. the replicate analysis of solutions containing 1 and 10 pg of bismuth were 7.1 and 5.3% (n=10), respectively. However, the recoveries values obtained with urine and whole blood bismuth spiked samples were over 96.5% and the agreement between observed and certified values was good.
机译:描述了一种具有微波辅助样品消化的在线自动流动注射系统,用于电热原子吸收光谱法测定生物材料中的铋。在样品暴露于微波辐射之后,分析物经历沉淀/溶解过程。铋与锡离子在碱性介质中沉淀,并收集在打结线圈的壁上,而其他基质成分则向下游流动以产生废物。将沉淀物用硝酸溶解,并将子样品收集在采样臂组件的毛细管中,以通过正时注射器通过空气的正排量将20#μl的体积引入石墨管。首先通过用标准铋溶液填充采样臂,然后将等分试样溶液注入雾化器中,来评估分析品质因数。校准曲线从检测限(8 pg)到1.2 ng铋呈线性关系。 0.2 A-s的灵敏度为26.8#mu#g 1〜(-1),特征质量(m_o)为11.8 pg / 0.0044 A-s。通过重复分析含20和200 pg铋的溶液评估的方法的精度分别为5.5%和3.0%(n = 10)。将溶液引入此处所述的流动系统时,校准曲线在0.04-6.0#mu#g 1〜(-1)范围内呈线性,这意味着铋的预富集系数为10。精度略有下降,例如含1和10 pg铋的溶液的重复分析分别为7.1%和5.3%(n = 10)。但是,尿液和全血铋加标样品的回收率均超过96.5%,观察值与标准值之间的一致性很好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号