The influering effects due to the reagents and matix elements associated with a four step sequential extraction procedure on ICPOES determination of trace elements were investigated in a systematic way. The emission lines were selected in order to include the most interesting elements for environmental studies (Zn, Pb, Ni, Cr, V and Cu) and the concentrations ranged according with the values occurring in the real samples. In order to distinguish between chemical and physical interfering effects, the Mg 280.270-Mg 285.213 line intensity ratio was measured, in each condition. Both pneumatic and ultrasonic nebulization were considerred for comparison. It was found that both the elements which constitute the sample and the reagents which are added during the sample preparation steps significantly influence the emission intensity of all the analytes, depending on the analytical concentration and the nebulization system. Generally, the signal variations were higher with ultrasonic nebulization. Concerning the interference mechanisms, it was found that the effect of the major elements (Na, K, Mg, Ca, Al and Fe) is essentially relaed to a change of the aerosol generation and transport processes. Differently, acetic acid, ammonium acetate and hydroxylamine hydrochloride significantly improved the plasma excitation conditions, depending on their concentration. A change of the sample introduction efficiency due to the presence of these reagents was also evident. On the contrary, the effect of hydrochloric and nitric acid emerged to be related only to the processes occurring in the sample introduction system.
机译:系统地研究了与四步顺序萃取程序相关的试剂和胶体元素对ICPOES测定痕量元素的影响。选择排放线是为了包括环境研究中最有趣的元素(Zn,Pb,Ni,Cr,V和Cu),其浓度根据实际样品中的值而变化。为了区分化学干扰干扰和物理干扰干扰,在每种情况下均测量了Mg 280.270-Mg 285.213线强度比。比较了气动雾化和超声雾化。已经发现,构成样品的元素和在样品制备步骤中添加的试剂均会显着影响所有分析物的发射强度,具体取决于分析浓度和雾化系统。通常,超声波雾化的信号变化较大。关于干扰机制,发现主要元素(Na,K,Mg,Ca,Al和Fe)的作用基本上与气雾剂生成和传输过程的变化有关。不同地,乙酸,乙酸铵和盐酸羟胺根据其浓度显着改善了血浆激发条件。由于这些试剂的存在,样品引入效率的变化也很明显。相反,盐酸和硝酸的作用仅与样品引入系统中发生的过程有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号