首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination
【24h】

Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination

机译:固定有黄嘌呤氧化酶和碳基丝网印刷电极的安培法检测尿酸和次黄嘌呤。鱼类鲜度测定申请

获取原文
获取原文并翻译 | 示例
           

摘要

Carbon-based screen-printed electrodes are suitable for uric acid detection. Xanthine oxidase (XO) was immobilized either directly on the surface of the electrode or in a reactor with CPG aminopropylsilane in a FIA assembly. Higher reproducibility and lifetime was obtained with the reactor. Optimum conditions were found for the determination of Hypoxanthine (Hx), Inosine (HxR) and Inosine monophosphate (IMP). Calibration curves for IMP, HxR and Hx are linear up to 50 μM with detection limit of 1 μM for 50 μl injection. One assay is completed within 30 s.The reproducibility of 20 μM of Hx was obtained with CV 2%. # 1997 Elsevier Science B.V.
机译:碳基丝网印刷电极适用于尿酸检测。黄嘌呤氧化酶(XO)直接固定在电极表面或固定在FIA组件中的CPG氨基丙基硅烷的反应器中。用该反应器可获得更高的可重复性和寿命。找到了确定次黄嘌呤(Hx),肌苷(HxR)和肌苷一磷酸(IMP)的最佳条件。 IMP,HxR和Hx的校准曲线线性至50μM,进样50μl的检测极限为1μM。在30 s内完成一项测定。用2%的CV获得20μMHx的重现性。 #1997 Elsevier Science B.V.