首页> 外文期刊>Urology >Three-dimensional computer-simulated prostate models: lateral prostate biopsies increase the detection rate of prostate cancer.
【24h】

Three-dimensional computer-simulated prostate models: lateral prostate biopsies increase the detection rate of prostate cancer.

机译:三维计算机模拟前列腺模型:前列腺侧面活检可提高前列腺癌的检出率。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: Urologists routinely use the systematic sextant needle biopsy technique to detect prostate cancer. However, recent evidence suggests that this technique has a significant sampling error. We developed a novel three-dimensional (3D) computer-assisted prostate biopsy simulator based on whole-mounted step-sectioned radical prostatectomy specimens to compare the diagnostic accuracy of various prostate needle biopsy protocols. METHODS: We obtained digital images of 201 step-sectioned whole-mounted radical prostatectomy specimens. 3D computer simulation software was developed to accurately depict the anatomy of the prostate and all individual tumor foci. Additional peripheral devices were incorporated into the system to perform interactive prostate biopsies. We obtained 18 biopsies of each prostate model to determine the detection rates of various biopsy protocols. RESULTS: The 10- and 12-pattern biopsy protocols had a 99.0% detection rate; the traditional sextant biopsy protocol rate was only 72.6%. The 5-region biopsy protocol had a 90.5% detection rate and the 14-pattern, which includes all the biopsies used in the patterns above, only added 1 additional positive case (99.5%). Transitional zone and seminal vesicle biopsies did not result in a significantly increased detection rate when added to the patterns above. Only one positive model was obtained when the transitional zone biopsies were added. The lateral sextant pattern had a detection rate of 95.5%, and the 4-pattern lateral biopsy protocol had a 93.5% detection rate. CONCLUSIONS: Our results suggest that all the biopsy protocols that use laterally placed biopsies based on the 5-region anatomic model are superior to the routinely used sextant prostate biopsy pattern. Lateral biopsies in the mid and apical zones of the gland are the most important.
机译:目的:泌尿科医生通常使用系统的六分针穿刺活检技术来检测前列腺癌。但是,最近的证据表明该技术具有明显的采样误差。我们基于整个安装式阶梯切开式根治性前列腺切除术标本开发了一种新颖的三维(3D)计算机辅助前列腺活检模拟器,以比较各种前列腺穿刺活检方案的诊断准确性。方法:我们获得了201步切片的全安装式前列腺癌根治术标本的数字图像。开发了3D计算机仿真软件以准确描绘前列腺和所有单个肿瘤灶的解剖结构。其他外围设备被合并到系统中以执行交互式前列腺活检。我们获得了每个前列腺模型的18次活检,以确定各种活检方案的检出率。结果:10例和12例活检方案检出率为99.0%。传统的六分法活检方案率仅为72.6%。 5区域活检方案的检出率为90.5%,而14模式(包括以上模式中使用的所有活检)仅增加了1例阳性病例(99.5%)。当添加到上述模式中时,过渡区和精囊活检并未导致检测率显着提高。当添加过渡区活检时,仅获得一个阳性模型。外侧六分体图案的检出率为95.5%,而4式侧面活检方案的检出率为93.5%。结论:我们的结果表明,所有使用基于5区解剖模型的侧向活检的活检方案均优于常规使用的六分前列腺活检模式。最重要的是在腺体的中部和根尖进行侧面活检。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号