For non-hyperbaric purposes, the Baxter Flo-Gard 6201 volumetric pump is capable of infusing multiple types of fluids at rates of 1-1,999 ml x h(-1). We designed a study to determine flow accuracy of this pump at variable rates, fluid viscosities, and volumes over a range of chamber pressures. For hyperbaric use, the pump pressure sensor was adjusted. Sodium chloride solution 0.9% (NS), enteral formula, and packed red blood cells (PRBC) were infused at varying rates from 86.1 to 304 kPa (0.85 to 3.0 atm abs). For NS, measured compared to set flow rates ranged from 12.5% to -7.5% at settings of 1 and 5 ml x h(-1) from 86.1 to 304 kPa (0.85 to 3.0 atm abs) pressures, respectively. For NS infusions at a set rate of 100 ml x h(-1), the measured flow was identical to the set rate at all pressures. At flow settings of 1,999 ml x h(-1), the measured flow varied from the set flow by +/-4.9% Enteral infusion at 100 ml x h(-1) showed approximately a 3% increase in the measured vs. set flow rate. PRBC measured flow rates ranged from -0.4 to 6% of the set rate. During chamber compression and decompression, with set flow rates from 1 to 10 ml x h(-1), the measured flow was considerably less than expected during compression and more than expected during decompression. In conclusion, the Baxter Flo-Gard 6201 infusion pump demonstrated acceptable performance for infusing saline, enteral formula, and PRBC at low and high infusion rates into the pressurized monoplace hyperbaric chamber up to 304 kPa (3 atm abs), with the exception of low rates during compression and decompression.
机译:出于非高压目的,Baxter Flo-Gard 6201容积泵能够以1-1,999 ml x h(-1)的速度注入多种类型的流体。我们设计了一项研究,以确定在一定范围的腔室压力下,可变速率,流体粘度和容积下,该泵的流量精度。为了高压使用,调整了泵压力传感器。以86.1至304 kPa(0.85至3.0 atm abs)的不同速率注入0.9%的氯化钠溶液(NS),肠溶配方和堆积的红细胞(PRBC)。对于NS,与设定流量相比,在1和5 ml x h(-1)的压力下,压力分别为86.1至304 kPa(0.85至3.0 atm abs),设定流量为12​​.5%至-7.5%。对于以100 ml x h(-1)的设定速率进行的NS输注,测得的流量在所有压力下均与设定速率相同。在流量设置为1,999 ml xh(-1)时,测得的流量与设定流量相差+/- 4.9%,在100 ml xh(-1)时的肠内输注显示,测得流量与设定流量相比增加了约3% 。 PRBC测得的流速为设定流速的-0.4%至6%。在腔室压缩和减压过程中,将流速设置为1到10 ml x h(-1),测得的流量明显小于压缩期间的预期值,而大于减压期间的预期值。总之,Baxter Flo-Gard 6201输液泵在低和高输注速率(最高304 kPa(3 atm abs)的加压单人高压舱)中表现出可接受的性能,可将盐水,肠溶配方和PRBC输注至低压和高压压缩和解压缩期间的速率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号