VALUE OF VIRTUAL TOUCH TISSUE IMAGING QUANTIFICATION FOR EVALUATION OF ULTRASOUND BREAST IMAGING-REPORTING AND DATA SYSTEM CATEGORY 4 LESIONS

机译:虚拟触摸组织成像定量在评估超声乳腺成像报告和数据系统类别4方面的价值

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The purpose of the study was to evaluate the value of 2-D shear wave elastography (SWE) of virtual touch tissue imaging quantification (VTIQ) for ultrasound (US) Breast Imaging-Reporting and Data System (BI-RADS) category 4 lesions. One hundred sixteen lesions were subject to conventional US, conventional strain elastography (SE) of elasticity imaging (EI), acoustic radiation force impulse (ARFI)-induced SE of virtual touch tissue imaging (VTI) and VTIQ before biopsies. Of the 116 lesions, 69 (59.5%) were benign and 47 (40.5%) were malignant. Significant differences were found between benign and malignant lesions in EI score, VTI score and shear wave speed (SWS) on VTIQ (both p < 0.05). The cut-off values were EI score >= 4, VTI score >= 4 and SWS >= 3.49 m/s, respectively. The diagnostic performance of VTIQ in terms of area under receiver operating characteristic curve (AUROC) were the highest (i.e., AUROC = 0.907), in comparison with EI, VTI alone or a combination of both. The associated sensitivity, specificity and accuracy were 87.2%, 82.6% and 84.5%, respectively. The combination of VTI and VTIQ, however, was similar with US BI-RADS (p = 0.475) in sensitivity in that only two (4.3%) of 47 malignant lesions were misdiagnosed as benign that were BI-RADS category 4b on US. VTIQ is valuable to differentiate benign from malignant BI-RADS category 4 lesions, and the combination of VTI and VTIQ might be useful for patient selection before biopsy. (E-mail: xuhuixiong@ 126. com) (C) 2016World Federation for Ultrasound in Medicine & Biology.
机译:这项研究的目的是评估二维触摸波弹性成像技术(SWE)对超声(US)乳房成像报告和数据系统(BI-RADS)4类病变的虚拟触摸组织成像量化(VTIQ)的价值。 116处病变在活检前接受了常规US,弹性成像(EI)的常规应变弹性成像(SE),声辐射力脉冲(ARFI)诱导的虚拟触摸组织成像(VTI)和VTIQ的SE。在116个病变中,良性占69个(59.5%),恶性占47个(40.5%)。在EI评分,VTI评分和VTIQ上的横波速度(SWS)方面,良性和恶性病变之间存在显着差异(均p <0.05)。临界值分别为EI评分> = 4,VTI评分> = 4和SWS> = 3.49 m / s。与单独使用EI,VTI或两者结合使用相比,以接收器工作特性曲线下的面积(AUROC)计,VTIQ的诊断性能最高(即AUROC = 0.907)。相关的敏感性,特异性和准确性分别为87.2%,82.6%和84.5%。但是,VTI和VTIQ的组合在敏感性上与美国BI-RADS相似(p = 0.475),因为在美国,BI-RADS 4b类的47个恶性病变中只有两个(4.3%)被误诊为良性。 VTIQ对于区分良性和恶性BI-RADS 4类病变非常有价值,并且VTI和VTIQ的组合可能对活检前的患者选择有用。 (电子邮件:xuhuixiong @ 126. com)(C)2016世界医学和生物学超声联合会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号