Two detection systems, electro-optical system and photo-conducting system, are tested by the method suggested previously for determining the boundaries of broadband terahertz radiation in time-domain spectroscopy. From a series of measurements the error in determining the operation ranges is calculated. The terahertz spectrometer with an electro-optical detector based on a ZnTe (110) crystal of thickness 2 mm has the operation spectral range of 0.059 - 1.092 THz. The detector utilizing an iPCA-21-05-1000-800-h photo-conducting antenna with the same source of signal demonstrates a wider operation band ranging from 0.017 to 1.6 THz. The method developed makes it possible to experimentally compare the parameters of the considered terahertz spectrometers obtained under the same quality of adjustment.
机译:通过先前建议的方法来测试时域光谱中宽带太赫兹辐射的边界,对两个检测系统(电光系统和光电导系统)进行了测试。通过一系列测量,计算出确定操作范围的误差。具有基于厚度为2 mm的ZnTe(110)晶体的电光检测器的太赫兹光谱仪的工作光谱范围为0.059-1.092 THz。使用具有相同信号源的iPCA-21-05-1000-800-h光电导天线的检测器显示出从0.017到1.6 THz的较宽工作频带。所开发的方法可以通过实验比较在相同调整质量下获得的所考虑的太赫兹光谱仪的参数。