首页> 外文期刊>Quantum electronics >Study of thermooptic distortions of a Nd : YVO4 active element at different methods of its mounting
【24h】

Study of thermooptic distortions of a Nd : YVO4 active element at different methods of its mounting

机译:Nd:YVO4有源元件在不同安装方法下的热光畸变研究

获取原文
获取原文并翻译 | 示例

摘要

Thermooptic distortions of the active element of an axially diode-pumped Nd:YVO4 solid-state laser are studied at different methods of its mounting. The study was performed by the Hartmann method. A mathematical model for calculating the optical power of a thermal lens produced in the crystal upon pumping is developed and verified experimentally. It is shown that the optical power of a thermal lens produced upon axial pumping of the convectively cooled active element sealed off in a copper heat sink is half the optical power observed upon convective cooling of the active element without heat sink. The experimental and theoretical results are in good agreement.
机译:研究了轴向二极管泵浦Nd:YVO4固态激光器有源元件在不同安装方法下的热光畸变。该研究通过Hartmann方法进行。建立了数学模型,用于计算泵浦时晶体中产生的热透镜的光焦度,并进行了实验验证。示出了在轴向泵送密封在铜散热器中的对流冷却的有源元件时产生的热透镜的光焦度是在没有散热器的有源元件的对流冷却时所观察到的光焦度的一半。实验和理论结果吻合良好。