Wear particles from prosthetic implants have been shown to cause inflammatory synovitis and periprosthetic osteolysis. These particle-induced pathologies are manifestations of adverse cellular responses to phagocytosed particles. In this study, phagocytosis of polyethylene particles was analyzed using flow cytometry (FCM), and the clinical utility of FCM in diagnosing particle-induced synovitis was examined.Ultra high molecular weight polyethylene particles exhibited natural autofluorescence at fluorescein isothiocyanate wavelengths when determined by FCM. Using this autofluorescent property of the particles, peripheral blood monocytes (PBMs) phagocytosing the particles could be detected by autofluorescence emission from intracellular particles. This autofluorescence from PBMs increased with particles/cell ratio in a dose-dependent manner. Particle phagocytosis was also detectable in joint fluid cells obtained from the patients with particle-induced synovitis following total joint arthroplasty (TJA). Phenotypic analysis indicated that phagocytes were typically CD14(+)CD16(-) macrophages, with occasional CD14(+)CD16(+) macrophages. Interestingly, decreased autofluorescence intensity of CD14(+) cells was observed after arthroscopic drainage, suggesting that FCM was useful in examining whether the treatment was successful. In summary, these results indicate that FCM analysis offers a simple and useful method of detecting phagocytosis of polyethylene particles and estimating the severity of particle-induced synovitis in post-TJA patients.
机译:已显示来自假体植入物的磨损颗粒会引起炎性滑膜炎和假体周围骨质溶解。这些颗粒诱导的病理是对吞噬颗粒不利的细胞反应的表现。本研究使用流式细胞仪(FCM)分析聚乙烯颗粒的吞噬作用,并研究了FCM在诊断颗粒诱发的滑膜炎中的临床应用。通过FCM测定时,超高分子量聚乙烯颗粒在异硫氰酸荧光素波长下表现出自然自发荧光。利用颗粒的这种自发荧光特性,吞噬颗粒的外周血单核细胞(PBM)可以通过细胞内颗粒的自发荧光来检测。来自PBM的这种自发荧光以颗粒/细胞比例的方式以剂量依赖的方式增加。在全关节置换术(TJA)后从患有颗粒诱发性滑膜炎的患者获得的关节液中也可检测到颗粒吞噬作用。表型分析表明,吞噬细胞通常是CD14(+)CD16(-)巨噬细胞,偶有CD14(+)CD16(+)巨噬细胞。有趣的是,关节镜引流后观察到CD14(+)细胞的自发荧光强度降低,这表明FCM可用于检查治疗是否成功。总而言之,这些结果表明,FCM分析提供了一种简单而有用的方法,可检测TJA后患者中聚乙烯颗粒的吞噬作用并估算颗粒诱发的滑膜炎的严重程度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号