首页> 外文期刊>Thin-Walled Structures >Ultimate strength of bolted moment-connections between cold-formed steel members
【24h】

Ultimate strength of bolted moment-connections between cold-formed steel members

机译:冷弯型钢构件之间的力矩连接的极限强度

获取原文
获取原文并翻译 | 示例

摘要

The behaviour and design of bolted moment-connections between cold-formed steel members, formed by using brackets bolted to the webs of the section, is considered. The particular problem of the moment-capacity of such joints being lower than that of the cold-formed steel sections being connected because of web buckling, caused by the concentration of load transfer from the bolts, is addressed. In this paper, a combination of laboratory tests and finite element analyses is used to investigate this mode of failure. It is demonstrated that there is good agreement between the measured ultimate moment-capacity and that predicted by using the finite element method. A parametric study conducted using the finite element model shows that the moment-capacity of a practical size joint can be up to 20% lower than that of the cold-formed steel sections being connected. Web buckling so-caused must therefore be considered in the design of such connections.
机译:考虑了通过使用螺栓连接到型材腹板上的托架形成的冷弯型钢构件之间的弯矩连接的性能和设计。解决了这样的接头的具体问题,即由于螺栓集中的载荷集中引起的腹板屈曲,这种接头的扭矩能力低于连接的冷弯型钢的扭矩能力。在本文中,结合了实验室测试和有限元分析来研究这种失效模式。结果表明,所测得的极限弯矩承载力与采用有限元法预测的极限承载力具有良好的一致性。使用有限元模型进行的参数研究表明,实际尺寸接头的弯矩承载力可能比所连接的冷弯型钢构件的弯矩承载力低20%。因此,在设计此类连接时必须考虑造成的腹板屈曲。

著录项

  • 来源
    《Thin-Walled Structures》 |2003年第11期|p.1019-1039|共21页
  • 作者

    J.B.P. Lim; D.A. Nethercot;

  • 作者单位

    The Steel Construction Institute, Silwood Park, Ascot, Berkshire, SL5 7QN, UK;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 建筑结构;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号