首页> 外文期刊>Thin-Walled Structures >Equivalent thickness of cold-formed thin-walled channel sections with perforated webs under compression
【24h】

Equivalent thickness of cold-formed thin-walled channel sections with perforated webs under compression

机译:带压缩孔的腹板的冷弯薄壁槽型截面的等效厚度

获取原文
获取原文并翻译 | 示例

摘要

Cold-formed thin-walled channel sections with perforated webs (thermal studs) are widely used in external wall panels in cold regions to reduce the cold bridging effect. However, no design method appears to be available for this type of structure. A possible method is to convert the perforated web of a thermal stud into a solid one with a reduced thickness (which is referred to as the equivalent thickness) and then adopt an existing design method for solid sections (e.g. EN 1993-1-3). This paper presents the development of a method to calculate the equivalent web thickness. The equivalent thickness calculation equation is based on regression analysis of a large number of finite element simulation results of elastic local buckling strength of perforated plates under compression, considering the effects of a number of different design variables such as plate depth, thickness, perforation patterns and dimensions of the plate. The FE simulations were carried out using a general FE software. This study suggests that the equivalent thickness is mainly related to the plate width to thickness ratio, the total width of perforation at the critical section and the width of the perforation zone (total plate width between the first and last perforation). A regression equation has been proposed to relate the equivalent thickness to these parameters. To demonstrate the validity of the proposed equivalent thickness method, the compression strengths of a large range of perforated columns have been simulated by using either the original perforated sections or the equivalent solid section; and a comparison of the simulation results shows good agreement between the two sets of results.
机译:带冷壁的冷弯薄壁槽型材(热销)被广泛用于寒冷地区的外墙面板,以降低冷桥效应。但是,这种类型的结构似乎没有可用的设计方法。一种可能的方法是将热栓的穿孔腹板转换为厚度减小的实心腹板(称为等效厚度),然后对实心截面采用现有的设计方法(例如,EN 1993-1-3) 。本文介绍了一种计算等效纸幅厚度的方法的发展。当量厚度计算公式基于对多孔板在压缩状态下的弹性局部屈曲强度的大量有限元模拟结果的回归分析,其中考虑了许多不同设计变量的影响,例如板深,厚度,穿孔方式和板的尺寸。有限元模拟是使用通用有限元软件进行的。这项研究表明,当量厚度主要与板宽与厚度之比,关键部位穿孔的总宽度以及穿孔区域的宽度(第一和最后穿孔之间的总板宽)有关。已经提出了将等价厚度与这些参数相关联的回归方程。为了证明所提出的等效厚度方法的有效性,已经使用原始的穿孔截面或等效的实心截面模拟了大范围的穿孔柱的抗压强度。仿真结果的比较表明两组结果之间具有很好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号