首页> 外文期刊>Thin-Walled Structures >Behavior of biaxially-loaded rectangular concrete-filled steel tubular slender beam-columns with preload effects
【24h】

Behavior of biaxially-loaded rectangular concrete-filled steel tubular slender beam-columns with preload effects

机译:双向预应力矩形钢管混凝土细长梁柱的行为

获取原文
获取原文并翻译 | 示例

摘要

In composite construction, rectangular hollow steel tubular slender beam-columns are subjected to preloads arising from construction loads and permanent loads of the upper floors before infilling of the wet concrete. The behavior of biaxially loaded thin-walled rectangular concrete-filled steel tubular (CFST) slender beam-columns with preloads on the steel tubes has not been studied experimentally and numerically. In this paper, a fiber element model developed for CFST slender beam-columns with preload effects is briefly described and verified by existing experimental results of uniaxially loaded CFST columns with preload effects. The fiber element model is used to investigate the behavior of biaxially loaded rectangular CFST slender beam-columns accounting for the effects of preloads and local buckling. Parameters examined include local buckling, preload ratio, loading angle, depth-to-thickness ratio, column slenderness, loading eccentricity and steel yield strength. The results obtained indicate that the preloads on the steel tubes significantly reduce the stiffness and strength of CFST slender beam-columns with a maximum strength reduction of more than 15.8%. Based on the parametric studies, a design model is proposed for axially loaded rectangular CFST columns with preload effects. The fiber element and design models proposed allow for the structural designer to efficiently analyze and design CFST slender beam-columns subjected to preloads from the upper floors of a high-rise composite building during construction.
机译:在复合结构中,在填充湿混凝土之前,矩形空心钢管细长梁柱要承受由建筑荷载和上层楼板的永久荷载引起的预紧力。尚未通过实验和数值研究双向加载薄壁矩形矩形钢管混凝土(CFST)细长梁柱在预应力下的行为。在本文中,简要描述了为CFST细长梁柱开发的具有预压效果的纤维单元模型,并通过已有预应力单轴加载CFST柱的现有实验结果进行了验证。纤维单元模型用于研究预应力和局部屈曲影响的双轴加载矩形CFST细长梁柱的性能。检查的参数包括局部屈曲,预压比,加载角,深度与厚度比,立柱细长度,加载偏心率和钢屈服强度。所得结果表明,钢管上的预紧力显着降低了CFST细长梁柱的刚度和强度,最大强度降低了15.8%以上。在参数研究的基础上,提出了具有预载效应的矩形矩形CFST柱的设计模型。提出的纤维元件和设计模型使结构设计人员能够有效地分析和设计CFST细长梁柱,这些柱柱在建造过程中受到高层复合建筑高层的预应力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号