首页> 外文期刊>Thin-Walled Structures >Stress analysis on cold-formed C-purlins subjected to wind suction load considering the effective stiffness of anti-sag bar
【24h】

Stress analysis on cold-formed C-purlins subjected to wind suction load considering the effective stiffness of anti-sag bar

机译:考虑抗弯杆有效刚度的冷弯C条受风荷载的应力分析

获取原文
获取原文并翻译 | 示例

摘要

The anti-sag bar is frequently adopted as an effective solution to enhance the lateral stiffness of cold-formed steel puffins. In many existing methods (e.g. ED method), the anti-sag bar is treated as the rigid lateral bracing for cold-formed steel purlins, which may overestimate its bracing efficiency due to the local deformation of purlin web near the position connecting the anti-sag bar, which may significantly reduce the effective stiffness of anti-sag bar. This paper presents an investigation on the effective stiffness of anti-sag bar in bracing the cold-formed steel purlins accounting for the effect of the local deformation of purlin web, based on which an accurate approximation is also proposed. The influence of the effective stiffness of anti-sag bar on the out-of-plane bending moment over the purlin span is then studied using the analytical model presented in ED. Subsequently, new solutions for the maximum compressive and tensile stresses for purlins with one anti-sag bar at their mid-span section are then proposed with the influence of the effective stiffness of the anti-sag bar taken into account. The results of the proposed solutions are verified by comparing their predictions with the results from the finite element (FE) analysis. Comparisons with FE results made in this study also indicate that the predictions of the ED solution may significantly overestimate or underestimate the controlling stresses of cold-formed steel purlins with anti-sag bar in many cases.(C) 2015 Elsevier Ltd. All rights reserved.
机译:防下垂杆通常被用作提高冷弯型海雀的横向刚度的有效解决方案。在许多现有方法(例如ED方法)中,防下垂杆被视为冷弯钢pur条的刚性侧向支撑,由于pur条腹板在连接防倾板的位置附近局部变形,可能会高估其支撑效率。防下垂杆,可能会大大降低防下垂杆的有效刚度。本文研究了抗下垂杆在支撑冷弯型钢lin条时的有效刚度,并考虑了lin条腹板局部变形的影响,并在此基础上提出了精确的近似值。然后,使用ED中提供的分析模型研究了防下垂杆的有效刚度对pur条跨度上的平面外弯曲力矩的影响。随后,在考虑到抗下垂杆的有效刚度的影响的情况下,提出了一种新的解决方案,该方案针对在中跨段具有一个抗下垂杆的pur条的最大压缩应力和拉伸应力。通过将其预测结果与有限元(FE)分析的结果进行比较,可以验证所提出解决方案的结果。与本研究中的有限元结果进行的比较还表明,在许多情况下,ED解决方案的预测可能会大大高估或低估带有抗流挂条的冷弯钢pur的控制应力。(C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号