首页> 外文期刊>Thin-Walled Structures >Pre-stressing method and structural behaviour of a Tensairity dome with multiple inflated cushions
【24h】

Pre-stressing method and structural behaviour of a Tensairity dome with multiple inflated cushions

机译:带有多个充气垫的拉伸穹顶的预应力方法和结构性能

获取原文
获取原文并翻译 | 示例

摘要

This paper describes a novel type of Tensairity dome, which is composed of a tensegrity cable dome and several inflated cushions. The cushions and cable dome act as a whole in synergy, and the introduction of compressed air, which is an important part of the structure, extends the tensegrity concept. This study builds an illustrative numerical model and examines the feasibility of the proposed structure. The inflating amount of air for each cushion and influence of the inflating sequence are considered. The effect of the internal air pressure on the structural behaviour is investigated for several different load cases. The results demonstrate that pre-stressing can be introduced by inflating the cushions instead of the tensioning cables, which greatly facilitates the construction. The novel structure exhibits effective stiffness and integrity in several possible conditions, and the internal air pressure of approximately 500-3500 Pa can ensure the tensioning role of the cushions. The air pressure values should be determined according to the environmental conditions of the construction site.
机译:本文介绍了一种新型的Tensairity穹顶,它由一个拉紧的缆索穹顶和多个充气垫组成。垫子和电缆穹顶共同发挥整体作用,而压缩空气的引入是该结构的重要组成部分,扩展了张力概念,这是该结构的重要组成部分。这项研究建立了一个说明性的数值模型,并检验了所提出结构的可行性。考虑每个垫子的充气量和充气顺序的影响。对于几种不同的载荷工况,研究了内部气压对结构性能的影响。结果表明,可以通过给垫子充气而不是张紧电缆来引入预应力,这极大地方便了施工。这种新颖的结构在几种可能的情况下均显示出有效的刚度和完整性,大约500-3500 Pa的内部气压可确保垫子的张紧作用。气压值应根据施工现场的环境条件确定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号