In this paper, the lossless and lossy direct compression design (LLDC) is proposed for the wearable devices. The electrocardiogram (ECG), blood pressure (BP), and respiration (RESP) can be applied to the compression design for cardiovascular diseases. The proposed LLDC can detect the abnormal symptoms and dynamically change the compression modes with different sample intervals and data precisions. In our experiments, the symptoms are detected, and the transmitted power and temperature for the wearable devices are reduced. The compression ratios for ECG, BP, and RESP are up to 7.94, 6.06, and 6.51 with percentage root-mean-square difference less than 6.5%. For ECG, BP, and RESP, the energies of the wearable devices are reduced by 50%–87%, 38%–89%, and 41%–89%; the temperatures are reduced by 2.6 °C–4.2 °C, 1.3 °C–3 °C, and 1.7 °C–3.6 °C, respectively.
机译:本文提出了可穿戴设备的无损和有损直接压缩设计(LLDC)。心电图(ECG),血压(BP)和呼吸(RESP)可以应用于心血管疾病的压缩设计。所提出的LLDC可以检测异常症状并以不同的采样间隔和数据精度动态地改变压缩模式。在我们的实验中,可以检测到症状,并降低可穿戴设备的传输功率和温度。 ECG,BP和RESP的压缩率分别高达7.94、6.06和6.51,均方根差异百分比小于6.5%。对于ECG,BP和RESP,可穿戴设备的能量分别降低了50% 87%,87%,89%和89%。温度分别降低了2.6°C–4.2°C,1.3°C–3°C和1.7°C–3.6°C。